16
5.13.4
- Vacuum Pump Adaptor (Optional)
The kit can be installed in the water unit and
features a cannula adapter for
6.3 mm (1) and
flow control (4).
The pump connection hose is embedded in
the corrugated hose of the water unit and the
support (2) is provided with a device for
automatically switching the vacuum pump on and
off.
To activate suction: remove the vacuum pump suction (3) from its
holder (2). The vacuum pump will work automatically.
To adjust suction flow: to decrease the suction flow, turn adaptor's body (3)
away from the indicators (4). The more distant, the smaller the suction flow. For
the maximum suction flow, align the indicators (4).
To deactivate the suction: place the vacuum pump in its holder (2).
The cannula adapter (1) is removable for cleaning.
The cannula adapter (1) is removable, allowing the use of
11 mm.
Note: the vacuum pump (3) and the cannula are not part of this device and can be purchased separately.
5.14
- Emergency Battery (Optional)
The emergency battery was developed exclusively for emergency
situations where it is necessary to complete a procedure with no electricity on
the mains to supply the equipment.
The battery is automatically activated when there is a lack of power, or
when the equipment is disconnected from the mains. In this case the equipment
emits the "Battery Mode" warning (
section 5.16.1
).
The battery provides autonomy approximately 3 hours of operation, a
period that may vary according to the amount of commands executed by
equipment.
The LED (1) indicates the status of the battery according to the colors shown:
−
GREEN: battery ready for use (full charge).
−
BLUE: battery in critical condition - Connect the equipment to the mains power supply as soon as possible.
While charging the battery, the blue LED is blinking.
Note: when the BLUE LED On, all commands are blocked. Operation only with the equipment connected to the
mains. Upon reaching the maximum battery charge, the LED turns GREEN and unlocks the commands for
operation in battery mode again.
5.14.1
- Battery Charge Warning Sounds
In addition to the LED battery charge indicator, the Performance Table uses warning sounds, as shown
below:
−
"Battery Mode": the equipment is disconnected from the mains or there is a lack of mains power.
−
"Low Battery": the battery charge is less than 50% and must be recharged. While the equipment is not
connected to the mains, the warning sound will be repeated every 5 minutes.
−
"Discharged Battery": the battery charge is at a critical level. While the equipment is not connected to the
mains, the warning sound will be repeated every 3 minutes. When this occurs, all the equipment
commands are blocked.
−
"Full Battery": the battery reaches the maximum charge level. The system emits this warning sound only
once.
5.15
- Operating Lights
The Performance Table features lighting options through operating light with articulated arms that can
be attached to your frame or fixed to the floor or ceiling.
Содержание PERFORMANCE TABLE
Страница 1: ......
Страница 2: ......
Страница 24: ...24 11 Dimensional...
Страница 25: ...25 12 Simbology According to IEC 60601 1 and IEC 60878 standards...
Страница 35: ...35...
Страница 37: ......
Страница 38: ......
Страница 60: ...24 11 Dimensional...
Страница 61: ...25 12 Simbologia La simbolog a est en conformidad con las normas IEC 60601 1 y IEC 60878...
Страница 71: ...35...