40496501TH Draft Version
132
4
Spacing is abnormal, while Alarm Lamp is on and “ERROR HOMING” or “ERROR SPACING” is
displayed on LCD.
•
Paper rolled into Carriage?
No
Yes
•
Remove the printing paper.
▼
•
Carriage moves if Printer is restarted?
No
Yes
• Go to C.
▼
•
The cable to DC Motor connected properly?
Yes
No
•
Connect the cable properly.
▼
•
The cables to PRA-Board CN1 and CN10 connected properly?
Yes
No
•
Connect the cables properly.
▼
•
The cable to PMA-Board CN2 connected properly?
Yes
No
•
Connect the cable properly.
▼
•
Check the DC Motor wave form at PRA-Board. No problem?
FOW side: Measure between CN10-2 pin and SH13.
REV side: Measure between CN10-4 pin and SH13.
No
Yes
•
Replace PMA-Board. Recovered?
No
Yes
•
End
▼
•
Replace the junction cable.
▼
•
Check conduction at Cord Assy connecting to DC Motor. No problem?
FOW side: Examine between CN10-2 pin and DC Motor Red Terminal, with Interlock
Switch on.
REV side: Examine between CN10-4 pin and DC Motor Black Terminal, with Interlock
Switch on.
Содержание PACEMARK 4410
Страница 1: ...PACEMARK 4410 PRINTER SERVICE HANDBOOK...
Страница 52: ...40496501TH Draft Version 52 Figure 3 1 3 2 Parts Layout...
Страница 95: ...40496501TH Draft Version 95...
Страница 151: ...40496501TH Draft Version 151 No Yes End Replace PHA Board Recovered No Yes End Replace PMA Board...
Страница 168: ...XXXXXXXXTH Draft Version 8 5 Fig 8 5 45 38 38 40 42 39 44 44 122 41...
Страница 169: ...XXXXXXXXTH Draft Version 8 6 142 141 11 119 Fig 8 6...
Страница 170: ...XXXXXXXXTH Draft Version 8 7 Fig 8 7 105 102 61 33 104 100 101...
Страница 171: ...XXXXXXXXTH Draft Version 8 8 Fig 8 8 55...