40496501TH Draft Version
80
3.3.27 AG Sensor Frame / Start Searching Sensor
(1)
Remove Cover Assy Access / Cover Assy Side (R) / Cover Assy Side (L) /Cover Assy Front
/ Frame Assy Rear / Plate Front (stuck). (See 3.3.1)
(2)
Unscrew 2 screws
1
and remove Rear Plate
2
.
(3)
Unscrew 2 screws
3
and remove AG Sensor Cover
4
.
(4)
Unscrew 2 screws
5
, unplug the connector
6
and remove AG Sensor Frame
7
.
(5)
Unscrew the screw
8
and release the latch, then remove Start Searching Sensor Lever Assy
9
and Start Searching Sensor Cord
0
together.
(6)
Unscrew the screw
A
and unplug the connector
B
from I/F Board (CN9), then unplug Start
Searching Sensor Cord
0
.
(7)
For installation, reverse the removal procedure.
(Note on Installation)
1. In assembling AG sensor frame
7
, it should be pulled in the direction of arrow shown in the
figure.
2. After assembling the AG sensor frame
7
, check the AG plate gap as stated in Section 2 of
4 ADJUSTMENTS and execute the auto gap correction as stated in Section 3.
4
3
B
1
2
A
0
9
8
6
7
5
Содержание PACEMARK 4410
Страница 1: ...PACEMARK 4410 PRINTER SERVICE HANDBOOK...
Страница 52: ...40496501TH Draft Version 52 Figure 3 1 3 2 Parts Layout...
Страница 95: ...40496501TH Draft Version 95...
Страница 151: ...40496501TH Draft Version 151 No Yes End Replace PHA Board Recovered No Yes End Replace PMA Board...
Страница 168: ...XXXXXXXXTH Draft Version 8 5 Fig 8 5 45 38 38 40 42 39 44 44 122 41...
Страница 169: ...XXXXXXXXTH Draft Version 8 6 142 141 11 119 Fig 8 6...
Страница 170: ...XXXXXXXXTH Draft Version 8 7 Fig 8 7 105 102 61 33 104 100 101...
Страница 171: ...XXXXXXXXTH Draft Version 8 8 Fig 8 8 55...