Troubleshooting > 165
Error
350
351
352
353
Replace image drum
%ERRCODE%:%COLOR%
drum
life
The image drum has reached
the end of its life (alarm).
Error 350: Y
Error 351: M
Error 352: C
Error 353: K
Warning status takes effect at
cover open/close.
Error
560
561
562
563
Replace image drum
%ERRCODE%:%COLOR%
drum
life
The error occurs after the image
drum has reached the end of its
life.
Error 560: Y
Error 561: M
Error 562: C
Error 563: K
Message is displayed until the
image drum is replaced.
Error
354
Replace fuser
%ERRCODE%:
fuser life
The fuser has reached the end
of its life and printing will stop.
Warning status takes effect at
cover open/close.
Replace fuser.
Error
355
Replace belt
%ERRCODE%:
belt life
The transfer belt has reached
the end of its life and printing
will stop.
Warning status takes effect at
cover open/close.
Replace transfer belt.
Error
348
Check fuser
%ERRCODE%:
fuser missing
Open the top cover, check the
fuser is installed correctly and
close the cover.
If the code still appears, replace
the fuser.
Error
544
545
546
547
Check toner cartridge
%ERRCODE%:%COLOR%
improper lock lever
Toner cartridge lever has not
been locked.
Lock into place securely.
STATUS
/ CODE
MESSAGE
MEANING / ACTION