Oki Data CONFIDENTIAL
43605601TH Rev. 1
214 /
7.6
Fuse Checking
If the following errors occur, please check each fuse of the main board (BLA PCB). (Please re-
fer to Table 7-6)
Table 7-6 Fuse Errors
HEAT
IDUP
F2
F3
IC16
IC15
R336
F4
F1
Enlarged drawing 1 of the main (M32) board
Enlarged drawing 2 of the main (M32) board
RFID
KHEAD
YHEAD
MHEAD
CP13
F5
Fuse Name
Error Description
Insert Point
Main board
(M32 PCB)
F6
Hopping error
Paper s conveying error
Paper feed motor, fuser motor 24V
F5
Papers conveying error
ID UP/DOWN error
Belt motor, ID UP/DOWN motor 24V
F7
FAN error
Hopping error
Solenoid, FAN
Fuse cutter 24V
F4
Cover open
Sensor etc. 5V
F8
Service call 130 to 134 error
LED HEAD 5V
R346 The LED turned off without control began.
For controlling 3.3V
F501
Scanner does not work
Scanner unit 30V
F1
FAX PCB does not work
FAX PCB 5V
High Voltage
Board
F1
Cover open error
High voltage 24V
F2
POWER LSI error
High voltage 5V
Maker name Model name
Figure NO
Rated
current
Rated
voltage
Mounting place
Main
board
F4, F6, F7
F502
R346
LITTEL
0494 002NR
5402212S0202
2A
32V
Please reter to enlarged drawing 1
of the main M32 board parts.
F1, F5
LITTEL
0494 001NR
5402212S0102
1A
32V
Please reter to enlarged drawing 1
of the main M32 board parts.
F8
LITTEL
0494 003NR
5402212S0302
3A
32V
Please reter to enlarged drawing 2
of the main M32 board parts.
F501
LITTEL
0466 002NR
5402207S7202
2A
63V
Please reter to enlarged drawing 2
of the main M32 board parts.
High-
voltage
board
F1
WICKMAN
or
LITTEL(*1)
3821200
0663 002
---
2A
50V
Page 181 Please refer to the figure
of high-voltage power supply board
F2
WICKMAN
or
LITTEL(*1)
3821125
0663 1.25
---
1.25A
50V
Page 181 Please refer to the figure
of high-voltage power supply board
Fuse information list and Mounting place
*1 : Fuse F1 and F2 of the high-voltage board should be specified by WICKMAN or LITTEL
Содержание C3530n MFP
Страница 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Страница 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Страница 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Страница 86: ...43605601TH Rev 1 86 Oki Data CONFIDENTIAL Figure 4 2 3 20 Main motor Solenoid A A B clawC clawE clawD ...
Страница 105: ...43605601TH Rev 1 105 43420101 Holder Post Apply MOLYKOTE EM 30L to the hatched area EM 30L Class A ...
Страница 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Страница 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Страница 164: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 164 2 Service Call Error The service call error list is recording in table 7 1 2 ...
Страница 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Страница 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Страница 228: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 228 13 FAX circuit board PCB used for C3530MFP FX1 PCB Component side ...
Страница 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Страница 230: ...Please refer to the Illustrated Parts Manual for spare part information ...