Oki Data CONFIDENTIAL
43605601TH Rev. 1
168 /
Table 7-1-2 service call error list (4/6)
Display
Cause
Details of error
Method
Service call
190: Error
System memory
overflow
Does the error recur?
Yes
Turn on the power supply again.
Install an additional RAM DIMM.
Service call
200: Error
202: Error
PU Firmware
Download Error
Error occurs when the PU firmware
is rewritten
After the power supply is turned
on again, try to download again.
(Because this processing is
not performed during usual
operation, it does not occur.)
Service cal
l209:
Down Load
Error
Custom Media
Type table
download failure
Failed in downloarding
Custom Media Type Table
After the power supply is turned
on again, try to download again.
(Because this processing is
not performed during usual
operation, it does not occur.)
Service call
203: Error
204: Error
207: Error
208: Error
213: Error
214: Error
F0C: Error
FFE: Error
FFF: Error
CU program
trouble (203~214
are not generated
in usual
operation)
Incorrect processing is performed
by the CU program.
Does the error recur?
Turn on the power supply again.
Replace M32 board.
Service call
230: Error
RFID Reader not
Installed
RFID Reader Device error.
Does the error recur?
Yes
Yes
Check the connenction of the
LUM board (RFIS reader/writer
board).
Replace the LUM board (RFID
reader/writer board).
Replace the M32 board.
Service call
231: Error
RFID Reader I/F
Error
An interface error was detected
with the RFID reader device.
01: communication error between
the RFID reader and the engine
PCB.
02:the transcever circuit error of
the RFID reader.
03:communication error between
the RFID reader and the Tag chip.
04:the RFID Tag detection error
(more than 4chips).
01: Same as Error 230.
02: Replace the LUM board
(RFID reader/writer board).
03: Check the connection of the
antenna cable.
04: Check if the number of RFID
Tags is correct.
Service call
240: Error
Engine Program.
Memory Error
240: Flash Memory
Hardware Error
If the error occurs again after
returning on the power supply,
replace the board of the unit.
Service call
905: Error
906: Error
Short circuit
error of the
Frame thermistor
(thermistor
defect) is
detected
Does the error recur?
Yes Check the cable connection
between the ZAK board and M32
board and turn on the power
again.
Replace the fuser unit.
Replace the M32 board.
Service call
907: Error
High
temperature
error of the frame
thermistor (over
150)is detected
Does the error recur?
Yes Check the cable connection
between the ZAK board and M32
board and turn on the power
again.Replace the fuser unit.
Replace the M32 board.
Содержание C3530n MFP
Страница 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Страница 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Страница 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Страница 86: ...43605601TH Rev 1 86 Oki Data CONFIDENTIAL Figure 4 2 3 20 Main motor Solenoid A A B clawC clawE clawD ...
Страница 105: ...43605601TH Rev 1 105 43420101 Holder Post Apply MOLYKOTE EM 30L to the hatched area EM 30L Class A ...
Страница 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Страница 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Страница 164: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 164 2 Service Call Error The service call error list is recording in table 7 1 2 ...
Страница 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Страница 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Страница 228: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 228 13 FAX circuit board PCB used for C3530MFP FX1 PCB Component side ...
Страница 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Страница 230: ...Please refer to the Illustrated Parts Manual for spare part information ...