Oki Data CONFIDENTIAL
43605601TH Rev. 1
165 /
Table 7-1-2 service call error list (1/6)
Display
Cause
Details of error
Method
Service call
002: Error
005: Error
CPU Excepption
Is the error message displayed
again?
Yes
No
If the RAM DIMM is mounted,
remove it and turn the power
supply off/ON.
Replace M32 boardRemount
RAM DIMMReplace
RAMDIMM
Service call
030: Error
CU RAM
Check Error
Is the error message displayed
again?
Yes
Power supply OFF/ONReplace
M32 board
Service call
031: Error
CU Optical RAM
Check Error
Is RAM DIMM mounted normally?
Does it restore by exchanging RAM
DIMM?
No
Yes
No
Remount RAM DIMM
Replace RAMDIMM
Replace M32 board
Service call
040: Error
CU EEPROM
Error
Is the error message displayed
again?
Yes
Power supply OFF/ONReplace
M32 board
Service call
041:Error
CU Flash Error
Flash ROM Error
on the CU board
Is the error message displayed
again?
Yes
Power supply OFF/ONReplace
M32 board
Service call
042: Error
043: Error
Flash File
System Error
It failed to the access to CU Flash
ROM that is attached to the BLA
board directly.
The compulsive initialization
of Flash is done. (Because
NIC-F/W is deleted, please be
careful to it. After initialization,
it is necessary to write NIC-F/
W by the maintenance utility).
FLASH FORMAT is executed
by using the maintenance utility.
If the symptom doesn't change,
replace the M32 board.
Service call
072: Error
Engine I/F Error
I/F Error
between PU and
CU
Replace M32 board
Service call
073: Error
Video Error
When the image
data sprads,
defect is
detected.
(Incorrect data
receive)
Does the error recur?
Yes
Change the PC to high spec or
lower the resolution, and then
print again.
Replace M32 board
Service call
074: Error
075: Error
Video Error
When the image
data spreads,
defect is
detected.
Replace M32 board
Service call
081: Error
Difference
between version
of CU firm and
EEPROM
Does the error recur?
Yes
Do EEPROM Initialization.
(Turn on the power supply by
Cover-open & pressing ONLINE
switch & pressing CANCEL
switch).
Because the Mac address will
disappear with this initialization,
lease reset Mac address by
using the maintenance utility.
Replace M32 board
Service call
104: Error
EngineEEPROM
mounting check
is OK with turning
on the power
supply, after that,
lead/light error is
detected
Does the error recur?
Yes
Power supply OFF/ON
Replace M32 board
Содержание C3530n MFP
Страница 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Страница 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Страница 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Страница 86: ...43605601TH Rev 1 86 Oki Data CONFIDENTIAL Figure 4 2 3 20 Main motor Solenoid A A B clawC clawE clawD ...
Страница 105: ...43605601TH Rev 1 105 43420101 Holder Post Apply MOLYKOTE EM 30L to the hatched area EM 30L Class A ...
Страница 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Страница 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Страница 164: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 164 2 Service Call Error The service call error list is recording in table 7 1 2 ...
Страница 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Страница 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Страница 228: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 228 13 FAX circuit board PCB used for C3530MFP FX1 PCB Component side ...
Страница 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Страница 230: ...Please refer to the Illustrated Parts Manual for spare part information ...