Oki Data CONFIDENTIAL
43605601TH Rev. 1
197 /
7.5.2.(9) Fuser Error (Service call 170-177)
(9-1) Error occurred immediately after turning on the printer.
(9-2) Error occurred after turning on the printer for about 1 minute.
Note!
Because service call 171 error and 175 error may occur when the temperature of printer
is below zero, please restart the printer after making it warm when the temperature of
printer is low.
Confirmation Items
Confirmation Tasks
Action at NG
(9-1-1) Trouble of thermistor Note)
Upper thermistor,
lower thermistor, frame
thermistor, side thermistor
(only C3400)
Check whether short or open circuit exists.
Check the resistance value of connector pins on the
lower part of fuser.
(Refer to Chapter 8.1 check the resistance value
(Fuser))
Replace the fuser
with a new one.
When trying to use
a new fuser, please
utilize the fuse
keep mode of the
maintenance utility.
(See Note! on page
154.)
Mounting condition of
fuser
Is the connector of lower part of fuser pressed in
position in order to mount the fuser?
Reset the fuser.
Confirmation Items
Confirmation Tasks
Action at NG
(9-2-1) Temperature rise of fuser
Thermostat, halogen lamp Perform the heater control of fuser, and by hand check
whether the fuser is warmed up.
Check that the resistance value between 1pin-7pin of
connector is several
Ω
-several 10
Ω
with keeping the
printer cool.
(Refer to Chapter 8.1 check the resistance value
(Fuser))
Replace the fuser
with a new one.
When trying to use
a new fuser, please
utilize the fuse
keep mode of the
maintenance utility.
(See Note! on page
154.)
(9-2-2) Temperature rise of fuser
Installation of upper
thermistor
The upper thermistor may be installed out of position,
is the measured temperature lowered?
Remove the heater cover, by visual inspection check
whether bending of sensor occurs.
Replace the fuser
with a new one.
When trying to use
a new fuser, please
utilize the fuse
keep mode of the
maintenance utility.
(See Note! on page
154.)
Installation of lower
thermistor
If the lower thermistor is not contacted, would
the detected temperature be lower than actual
temperature?
Replace the fuser
with a new one.
When trying to use
a new fuser, please
utilize the fuse
keep mode of the
maintenance utility.
(See Note! on page
154.)
(9-2-3) AC input for halogen
AC voltage of low-voltage
power supply
Is AC voltage supplied for heater normally?
Between 1-3pin and 3-4pin of CN2 connector of
power supply
Replace the low-
voltage power
supply.
Heater ON signal
outputted from PU to low-
voltage power supply
Check whether heater ON signal is activated in the
warming-up timing. L is activated during ON.
20pin of POW connector of main board (M32 PCB)
Replace the main
board M32 PCB)
with a new one.
Содержание C3530n MFP
Страница 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Страница 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Страница 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Страница 86: ...43605601TH Rev 1 86 Oki Data CONFIDENTIAL Figure 4 2 3 20 Main motor Solenoid A A B clawC clawE clawD ...
Страница 105: ...43605601TH Rev 1 105 43420101 Holder Post Apply MOLYKOTE EM 30L to the hatched area EM 30L Class A ...
Страница 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Страница 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Страница 164: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 164 2 Service Call Error The service call error list is recording in table 7 1 2 ...
Страница 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Страница 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Страница 228: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 228 13 FAX circuit board PCB used for C3530MFP FX1 PCB Component side ...
Страница 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Страница 230: ...Please refer to the Illustrated Parts Manual for spare part information ...