Oki Data CONFIDENTIAL
43605601TH Rev. 1
156 /
No.
Level
Function
PJLStatusCode
Status Message
168
Error
Scanner communications error: Data was sent to the
scanner with the container length or the additional data
length specified larger or smaller than the data container.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
(Function name)
Power Off/On
Scanner Invalid Data Length
%TIMING%, %CODE%
40769
169
Error
Scanner communications error: Data was sent to the
scanner with the container length specified larger or smaller
than the command container.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
(Function name)
Power Off/On
Scanner Invalid Command Length
%TIMING%, %CODE%
40770
170
Error
Scanner communications error: Data was sent to the
scanner with invalid data specified in the data container.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
(Function name)
Power Off/On
Scanner Invalid Data
%TIMING%, %CODE%
40771
171
Error
Scanner communications error: Data was sent to the
scanner with invalid parameters specified in the command
container.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
(Function name)
Power Off/On
Scanner Invalid Parameter
%TIMING%, %CODE%
40772
172
Error
Scanner communications error: Invalid container length,
protocol type, container type, or additional data are sent to
the scanner.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
(Function name)
Power Off/On
Scanner Invalid Value
%TIMING%, %CODE%
40773
Содержание C3530n MFP
Страница 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Страница 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Страница 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Страница 86: ...43605601TH Rev 1 86 Oki Data CONFIDENTIAL Figure 4 2 3 20 Main motor Solenoid A A B clawC clawE clawD ...
Страница 105: ...43605601TH Rev 1 105 43420101 Holder Post Apply MOLYKOTE EM 30L to the hatched area EM 30L Class A ...
Страница 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Страница 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Страница 164: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 164 2 Service Call Error The service call error list is recording in table 7 1 2 ...
Страница 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Страница 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Страница 228: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 228 13 FAX circuit board PCB used for C3530MFP FX1 PCB Component side ...
Страница 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Страница 230: ...Please refer to the Illustrated Parts Manual for spare part information ...