Oki Data CONFIDENTIAL
43605601TH Rev. 1
130 /
No.
Level
Function
PJLStatusCode
Status Message
57
Error
Scanner communications error: Data was sent to the
scanner with invalid parameters specified in the command
container.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
Power Off/On
Scanner Invalid Parameter
%TIMING%, %CODE%
40772
58
Error
Scanner communications error: Invalid container length,
protocol type, container type, or additional data was sent
to the scanner.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
Power Off/On
Scanner Invalid Value
%TIMING%, %CODE%
40773
59
Error
Scanner communications error: Invalid command was sent
to the scanner.
This message is displayed until the Stop button is pressed.
%CODE%
0x01 - 0x0F
%TIMING%
Command Container
Data Container
Response Container
1
2
3
4
5
Power Off/On
Scanner Invalid Command
%TIMING%, %CODE%
40774
60
Error
Lamp error has occurred.
1
2
3
4
5
Power Off/On
Scanner Lamp Error
40779
61
Error
Home sensor error has occurred.
1
2
3
4
5
Power Off/On
Scanner Home Sensor Error
40780
62
Error
Sensor error has occurred.
1
2
3
4
5
Power Off/On
Scanner Sensor Error
40781
Содержание C3530n MFP
Страница 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Страница 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Страница 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Страница 86: ...43605601TH Rev 1 86 Oki Data CONFIDENTIAL Figure 4 2 3 20 Main motor Solenoid A A B clawC clawE clawD ...
Страница 105: ...43605601TH Rev 1 105 43420101 Holder Post Apply MOLYKOTE EM 30L to the hatched area EM 30L Class A ...
Страница 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Страница 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Страница 164: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 164 2 Service Call Error The service call error list is recording in table 7 1 2 ...
Страница 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Страница 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Страница 228: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 228 13 FAX circuit board PCB used for C3530MFP FX1 PCB Component side ...
Страница 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Страница 230: ...Please refer to the Illustrated Parts Manual for spare part information ...