Oki Data CONFIDENTIAL
43605601TH Rev. 1
169 /
Table 7-1-2 service call error list (5/6)
Display
Cause
Details of error
Method
Service call
908: Error
Low temperature
error of the
Frame
thermistor
(lower than
[environment
temperature -10])
is detected
Does the error recur?
Yes Check the cable connection
between the ZAK board and M32
board and turn on the power
again.
Replace the fuser unit.
Replace the M32 board.
923: Error
Image Drum Lock
Error
The ID motor does not rotate
correctly.
Is the error message displayed
when the power is turned on again?
Yes
Yes
Check if the ID unit is set
correctly.
Replace the ID unit.
Replace the ID motor.
Service call
980: Error
Media coiling
error to the fuser
Media is coiled to the fuser
Turn off the power supply.
Replace the fuser.
Service call
981: Error
Difference
between PU
model version
detected and CU
model version
detected
Does the error recur?
Yes
Turn off/on the power supply.
Replace the M32 board.
High-voltage
power supply
I/F error when
initializing
Is the cable between PU board and
the high-voltage power supply unit
correctly connected?
Isn’t there defective contact point?
No
Yes
No
Reconnect correctly.Check the
defective contact point of high-
voltage system.
Replace the high voltage power
supply.
PU board SRAM
error
Does the error recur?
Yes
Turn off the power supply again
Replace the M32 board
CRC check error
of PU download
data
After PU data is downloaded (PU
fireware, custom media data, head
correction data), CRC check error
is detected.
After the power supply is turned
on again, try to download again.
(Because this processing is
not performed during usual
operation, it does not occur.)
PU board Flash
ROM hash check
error
Does the error recur?
Yes
Turn on the power supply again
Replace the M32 board
PU board Flash
ROM writing error
Does the error recur?
fter the power supply is turned
on again, try to download again.
(Because this processing is
not performed during usual
operation, it does not occur.)
The
communication
error with ASIC
on the CU board
is detected
Replace the M32 board.
Service call
F0C: Error
System Call
Exception
Send the hard copy of
StatusPage to a related
department when the power
supply OFF/ON is normal.
Service call
FFF: Error
Bus controller
ROM Write
protection
Send the hard copy of
StatusPage to a related
department when the power
supply OFF/ON is normal.
Содержание C3530n MFP
Страница 1: ...Oki Data CONFIDENTIAL C3530nMFP Maintenance Manual 032807A ...
Страница 8: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 ...
Страница 50: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 50 Sample In case of C3530MFP 2 ...
Страница 86: ...43605601TH Rev 1 86 Oki Data CONFIDENTIAL Figure 4 2 3 20 Main motor Solenoid A A B clawC clawE clawD ...
Страница 105: ...43605601TH Rev 1 105 43420101 Holder Post Apply MOLYKOTE EM 30L to the hatched area EM 30L Class A ...
Страница 108: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 108 ...
Страница 109: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 109 ...
Страница 164: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 164 2 Service Call Error The service call error list is recording in table 7 1 2 ...
Страница 220: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 220 ...
Страница 221: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 221 ...
Страница 228: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 228 13 FAX circuit board PCB used for C3530MFP FX1 PCB Component side ...
Страница 229: ...Oki Data CONFIDENTIAL 43605601TH Rev 1 229 229 Solder side ...
Страница 230: ...Please refer to the Illustrated Parts Manual for spare part information ...