Operating limit temperatures, space heating
Heat pump model
VMi 6
VMi 9
VMi 11
VMi 14
VMi 17
Average
TOL
°C
–10
–10
Warmer
TOL
°C
–22
–22
Colder
TOL
°C
+2
+2
Seasonal power consumption, space heating
Heat pump model
VMi 6
VMi 9
VMi 11
VMi 14
VMi 17
Average
QHE/A
kWh/a
4116
5296
5296
7443
8716
Warmer
QHE/W
kWh/a
4786
6181
6899
8645
10145
Colder
QHE/C
kWh/a
2695
3418
3837
4819
5634
Power consumption in modes other than active mode
Off mode
P
OFF
kWh
0.017
Standby mode
P
SB
kWh
0.017
Thermostat off mode
P
TO
kWh
0.017
Cranckase heater mode
P
CK
kWh
0.017
Other data
Heat pump model
VMi 6
VMi 9
VMi 11
VMi 14
VMi 17
Storage tank charge time
h:min
2:13
1:45
1:30
1:11
1:01
Electric power required for charging storage
tank
kWh
4.24
4.43
4.11
4.10
4.31
Power consumption in standby
kW
0.108
0.113
0.106
0.106
0.111
Indicative DHW temperature
°C
49
Maximum DHW volume
l
398
408
416
431
442
Simulated daily consumption
Load profile
XL
Power consumption
kWh
5.69
5.95
5.52
5.50
5.78
COP
DHW
3.67
3.51
3.78
3.80
3.61
Energy efficiency class
–
–
–
–
–
Heat pump operating limits
Minimum temperature, heat source
°C
–10
Maximum temperature, heat source
°C
+15
Minimum initial temperature for DHW
°C
+20
Maximum constant DHW temperature
°C
+52
Name and address of the manufacturer
Suomen Lämpöpumpputekniikka Oy, Unikontie 2, FI-62100 Lapua, Finland
70 (70)
M8011 2204EN
Содержание VSi 6-14
Страница 1: ...M8011 2204EN 25 January 2022 Installation and operation manual VSi 6 14 VMi 6 17 ss Control...
Страница 2: ......
Страница 59: ...Dimensional drawings VSi 10VS14_2 VSI 1 ver 1 10VS14_2 VSI 2 ver 1 M8011 2204EN 57 70...
Страница 60: ...Dimensional drawings VMi 10VMI141_2 VMI 1 ver 1 10VMI141_2 VMI 2 ver 1 58 70 M8011 2204EN...
Страница 73: ......