Both the original heating curve and the adjusted curve will be displayed in the
Heating
curves
view.
To return room temperature to its original level, set the value to 0 °C.
4.4.2 Room temperature change with room temperature measurement active
If an optional room temperature sensor has been installed and activated, the current
room temperature and the target value for room temperature will be displayed in the
Room temperature change
view.
Changing room temp, measurement available ver. 1
1. Select the applicable heating circuit or circuits with buttons 1, 2, and 3.
2. To change the target value for room temperature, check the current room
temperature value, and specify a new target value in the
Setting
field.
3. If necessary, increase the speed at which room temperature is changed.
a. Press the cogwheel button along the bottom of the screen.
The
Room temperature change extra settings
view appears.
Room temperature additional settings ver. 1
b. Adjust the temperature change rate with the
Compensation multiplier
slider. With a compensation multiplier of 7, the temperature changes 7 times
faster than with a multiplier of 1. A higher compensation multiplier may cause
fluctuations in room temperature.
4. Return to the main view by pressing the house button or the left arrow.
4.4.3 Hot water intensification – temporary boost to hot water output
This function allows you to temporarily boost domestic hot water production for long
showers and other uses where a lot of warm water is required.
M8011 2204EN
29 (70)