Seasonal performance factor, VSi 6–14
Heat pump
VSi 6
VSi 8
VSi 10
VSi 12
VSi 14
Domestic hot water
SPF
dhw
4.02
3.77
3.89
3.83
3.81
SPF
spaces
0/35
5.00
4.69
4.84
4.77
4.75
SPF
spaces
0/45
4.02
3.77
3.89
3.83
3.81
SPF
spaces
0/55
3.39
3.18
3.28
3.23
3.22
Space heating
SPF
spaces
0/60
3.15
2.96
3.10
3.01
3.00
Seasonal performance factors in accordance with he National Building Code of Finland.
Seasonal performance factor, VMi 6–17
Heat pump
VMi 6
VMi 9
VMi 11
VMi 14
VMi 17
Domestic hot water
SPF
dhw
3.77
3.89
3.99
3.92
3.89
SPF
spaces
0/35
4.69
4.84
4.97
4.88
4.84
SPF
spaces
0/45
3.77
3.89
3.99
3.92
3.89
SPF
spaces
0/55
3.18
3.28
3.37
3.31
3.28
Space heating
SPF
spaces
0/60
2.96
3.05
3.13
3.08
3.05
Seasonal performance factors in accordance with he National Building Code of Finland.
6.5 Brine circuits
Pump data, VSi 6–14
Heat pump
VSi 6
VSi 8
VSi 10
VSi 12
VSi 14
Pump’s energy class
A (variable frequency drive)
Pump’s nominal input power
W
5–89
10–170
Pump speed, factory setting
%
90
Nominal flow, ΔT=3K*
l/s
0.47
0.64
0.79
0.89
1.13
Maximum allowed external pressure loss,
ΔT=3K*
kPa
66
52
96
85
57
Nominal flow, ΔT=4K*
l/s
0.35
0.48
0.59
0.67
0.84
Max. allowed external pressure loss, ΔT=4K* kPa
68
57
104
100
82
*ISO 14511.
62 (70)
M8011 2204EN