50 H / M / MH
90 H / M / MH
Burner
Mounting dimensions, mm
ø D2
R1
L
50 H / M / MH
165
117.5-135
240 / 300
Burner
Mounting dimensions, inches
ø D2
R1
L
50 H / M / MH
6.50
4.63–5.31
9.45 / 11.81
90 H / M / MH
8.27
11.81 / 15.75
To mount the burner:
1. Prepare the boiler front plate according to the given dimensions.
2. Coat the bolt threads with graphite-bearing grease prior to fitting.
3. Install the burner so that the motor shaft lies horizontally.
4. Remove the transportation bracket after the burner is attached to the boiler.
5. Make sure there is enough free space on the side to allow the burner to swing fully
open.
As standard, the burner swings to the left. The GKP-90 MH model can also be hinged
to the right side.
Install burner firmly. Vibration may damage burner or its components.
Switch off electric power from the burner before burner swing-out.
M5164 1640EN
21 (95)
Содержание GKP-50 MH
Страница 2: ......
Страница 21: ...3 3 Installing burner GKP 50 MH main dimensions D048897 ver 3 M5164 1640EN 19 95...
Страница 98: ...96 95 M5164 1640EN...
Страница 99: ......
Страница 100: ...Tarmontie 4 FI 15860 HOLLOLA FINLAND Tel 358 3 85 761 Fax 358 3 857 6239 Email info oilon com www oilon com...