Burner model
K
L
N
GKP-50
4 mm
0.16 inches
4 mm
0.16 inches
5 mm
0.20 inches
GKP-90
4 mm
0.16 inches
6 mm
0.24 inches
7 mm
0.28 inches
4.3 Oil pump pressure regulation
Fit a pressure gauge in the pressure gauge connection (see section
Oil pump
). Adjust
the oil pressure by turning the pressure regulating screw. The pressure increases by
turning the screw clockwise and decreases counter-clockwise.
When the pressure is altered, the oil flow and pressure follow the following formula:
V1
capacity marked on the nozzle
V2
nozzle capacity at a pressure of P2
P1
7 bar gives USgal/h
P2
pressure to be used
Example
Nozzle capacity when the nozzle size is 9 kg/h (2.5 USgal/h) and pressure 13 bar is
calculated as follows.
According to USgal:
4.4 Defining burner capacity
If you know the nozzle size, you can calculate the burner capacity as follows:
Nozzle size 6.55 kg/h
Pressure to be used 10 bar
● According to the CEN standard
P = kg/h x Hu x kp
P = 6.55 kg/h x 11.86 x 1~ 77 kW
● According to USgal
P = USgal/h x Hu x 3.2 x kp
P = 1.75 USgal/h x 11.86 x 3.2 x 1.2 ~ 79 kW