Aviator 3000 Series
EN-15
5. SCALE SETTINGS
5.1 Accessing the User Setup Mode
Press [PLU] [4] [4] [4] [4]. “
oP
” will be displayed, then press [FIX].
To navigate in the User Setup Mode:
Press [FIX] to accept the displayed setting and proceed to the next step
Press [>T<] to toggle through available settings
Press [>0<] to return to the previous steps
Press [PLU] to end setup and proceed to “Save”
5.2 User Setup Parameters
Window Display
Weight
Unit
Price
Description
Available Settings
oP
StEP 1
Key-press
beeper
ON
: Enables this function
OFF : Disables this function
Step 2
Sleep /
Automatic
Power-off
(battery
operation only)
0 : Sleep mode disabled / Auto-off disabled
1 : Sleep mode disabled / Auto-off after 30 min.
2 : Sleep mode after 5 min. / Auto-off disabled
3 : Sleep mode after 5 min. / Auto-off after 30
min.
4 : Sleep mode after 15 min. / Auto-off disabled
5
: Sleep mode after 15 min. / Auto-off after 30
min.
Step 3
Automatic
clearing of tare
and unit price
ON
: Auto-clear when weight is removed from
the pan
OFF : Manual clear by pressing [C]
Step 4
Pre-pack (Fix)
Mode
ON
: Enables this function
OFF : Disables this function
Step 5
Auto PLU
ON : Search PLU automatically
OFF
: Search PLU after pressing [PLU]
Step 6
1 or 2 PLU’s
per M-key
ON
: 2 PLU’s can be stored per M-key
OFF
: Only 1 PLU can be stored per M-key
Step 7
Filtering level
0 : No filtering
1 : Low (faster display speed)
2
: Normal
3 : High
Step 8
Communication
0
: “P” command
1
: command output and “P” command
2
: steady output
3
: continuous output
Save
Save or Abort
Save : Saves changes and restarts to weighing
mode
Abort : Restarts to weighing mode without saving
changes
Note:
Bold
settings are default
Содержание A32P3T series
Страница 2: ......
Страница 24: ...EN 22 Aviator 3000 Series 8 2 Drawings...
Страница 28: ......
Страница 51: ...Aviator serie 3000 ES 23 8 2 Dibujos...
Страница 78: ...FR 24 S rie Aviator 3000 8 2 Sch mas...
Страница 82: ......
Страница 83: ...Aviator serie 3000 ES 27...