background image

© Adam Equipment Company 2014 

Adam Equipment 

LBK SERIES 

(P.N. 9596, Revision D, July 2014) 

99 Washington Street 
Melrose, MA 02176 
Phone 781-665-1400
Toll Free 1-800-517-8431

Visit us at www.TestEquipmentDepot.com

Содержание LBK Series

Страница 1: ...dam Equipment Company 2014 Adam Equipment LBK SERIES P N 9596 Revision D July 2014 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 2: ... Adam Equipment Company 2014 ...

Страница 3: ...dam Equipment Company 2014 Easy Reference Model name of the scale Serial number of the unit Software revision number Displayed when power is first turned on Date of Purchase Name of the supplier and place ...

Страница 4: ... Adam Equipment Company 2014 1 ...

Страница 5: ... 9 5 4 USER FUNCTIONS 9 5 4 1 PARTS COUNTING FUNCTION 9 5 4 2 PERCENTAGE WEIGHING 10 5 4 3 CALIBRATION 10 6 0 FUNCTION SETTING 11 6 1 ENTERING THE FUNCTION SETTING MODE 11 6 2 SETTING OF AUTO SHUT OFF FUNCTION 11 6 3 BACKLIGHT SETTING MODE 11 6 4 PARTS COUNTING FUNCTION 12 6 5 PERCENTAGE WEIGHING FUNCTION 12 6 6 USER CALIBRATION FUNCTION 12 6 7 SELECTION OF WEIGHING UNITS 13 7 0 CALIBRATION 14 7 1...

Страница 6: ... Adam Equipment Company 2014 3 ...

Страница 7: ...ted Four models 3kg 6lb X 0 5g 0 001lb 6kg 12lb X 1g 0 002lb 12kg 25lb X 2g 0 005lb 30kg 65lb X 5g 0 01lb Large LCD with backlight 5 weighing units g kg lb oz and lb oz Indicators for Stable zero net weight and low battery functions Stainless steel pan with ABS case and pan support Sealed Membrane keypad Overload Protection Spirit level and leveling feet Auto calibration zero tracking and tare ...

Страница 8: ...seconds 2 seconds 2 seconds 2 seconds Operating temperature 0ºC to 40ºC 32ºF to 104ºF Humidity 10 80 Power supply LBK models AC 220 240 V 50 60 Hz 100mA and 6V 4Ah rechargeable battery LBK a models 12VDC 800mA adapter and 6V 4Ah rechargeable battery Calibration External calibration Calibration Weights 1Kg 2Kg 3Kg or 2lb 4lb 6lb 2Kg 4Kg 6Kg or 4lb 8lb 12lb 4kg 8kg 12kg or 10lb 20lb 25lb 10kg 20kg 3...

Страница 9: ...tended period Before operating parts marked with a symbol please read the instruction manual and operate with caution to avoid hazard Do not stack material on the scale when it is not in use Avoid high humidity that might cause condensation and keep away from direct contact with water Static may influence the weighing result To reduce the static wipe the pan and the scale with anti static wipes 4 ...

Страница 10: ...n to the polarity The red connector goes to the positive terminal on the battery the black connector goes to the negative terminal on the battery The power cord or DC adapter provided with the scale is used to charge the battery Make certain the power cord DC adapter matches the voltage of the location you are using the scale in Internal rechargeable batteries where used can be changed but please ...

Страница 11: ...en it will begin it s self checking test from 0 to 9 When the reading is stable the display will show 0 00 stable symbol zero symbol and the weighing unit used the last time the scale was used Press Unit to select units g Kg lb oz Lb z Check if the reading is 0 00 if not press Zero 0 00 and the zero symbol will be displayed Put the item to be weighed on the pan When the reading is stable the net w...

Страница 12: ...ons can be accessed using the Func key if the functions have been enabled as described in section 6 If the function is turned off the function will not be available Only functions that have been turned on can be accessed 5 4 1 PARTS COUNTING FUNCTION In normal weighing mode press Func key to move to parts counting mode The display will show PC 10pcs press Tare key to go through the preset sample p...

Страница 13: ... weighing mode 5 4 2 PERCENTAGE WEIGHING In the weighing mode press Func key twice to access the percentage weighing mode the display will show PER Press Zero key to set the reference sample value the display will show SE Place the item to be set at 100 on the pan and press Zero Key when the stability indicator comes on The display will show 100 0 When another item with a different weight value is...

Страница 14: ... PWR means that the function is disabled XX PWR means that the auto off function is on XX is the time before the scale will shut off automatically The number is in minutes To continue to other function settings press Unit to confirm the current setting and show the next mode The display will then show OFF bL On bL or AuTo bL these are the backlight function settings 6 3 BACKLIGHT SETTING MODE Pres...

Страница 15: ... this function OFF PEr the percentage function is off ON PEr the percentage function if on Press Unit key to confirm the setting and look through the next setting It enters user s simple cal function when it displays On CAL or OFF CAL 6 6 USER CALIBRATION FUNCTION Press Tare key to switch on or off the function OFF CAL the function is off ON CAL the function is on when the user cal function is off...

Страница 16: ...use The grams unit is always on Press Tare key to change the unit from on to off On the unit is activated Off the unit is disabled All the units will be in the following sequence Kg lb oz Lb Z Press Unit key to confirm and move to the next unit After the last weighing unit is set the display will go back to the first function Auto Off To leave the Function Settings section turn the scale off and o...

Страница 17: ...ghing mode press Func key to access calibration mode The display will show CAL Press Zero key an access code Pin code is required to continue The display will show Pin To enter the access code press the Func key Unit key and Tare key in sequence then press the Zero key to confirm the pin code The display will show the weighing unit last used to calibrate the scale S Unit kg or S Unit Lb press Unit...

Страница 18: ...g after 3 seconds If it is outside of the previous calibration value by more than 5 it will show FAIL L or FAIL H indicating the new calibration weight was too low FAIL L or too high FAIL H in respect to the previous calibration value 8 0 ERROR MESSAGE ADO A D counts are too high ADL A D counts are too low ERR Wrong operation Unit E All the units are disabled Low battery indication LBK 3 6a LBK 6 ...

Страница 19: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CA...

Страница 20: ...Scales Crane scales Mechanical and Digital Electronic Health and Fitness Scales Retail Scales for Price computing Copyright by Adam Equipment Co All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technology features specifications and desig...

Отзывы: