3.
If set to store two PLU’s per M-key, press and hold the desired
M-key until the long beep, then quickly press the M-key again
within 1 second. “
L2
” appears momentarily to indicate the data
is stored in the second memory location of that M-key
.
4.8.2.2 Recalling a PLU from the M-Key
1.
Press the M-key with the pre-stored data. The corresponding
Unit Price/Tare value will be displayed.
2.
If set to store two PLU’s per M-key, quick press the M-key twice
within 1 second.
“
L2
” appears momentarily, then the
corresponding Unit Price/Tare value.
Note: If pressing an M-key with no st
ored data, “
noPLu
” will show
momentarily in the Weight display.
4.9 By-Count Function (Version B)
The By-Count function is used as reference to calculate the price of non-
weighing items, e.g., the price for 36 pieces when 3 pieces cost a total of
$1.50.
1. Enter the deal quantity (1-
99), e.g., “
3
”, then press [X]. The X
annunciator will turn on to indicate the scale is in the By-Count mode.
annunciator will turn on to indicate the scale is in the By-Count mode.
2.
Enter the deal price, e.g., “
1.50
”, then press [FIX]. The Unit Price
display will show “1.50”.
display will show “
1.50
”.
3.
Enter the quantity to be sold, e.g., “
36
”. The resulting total price of
“
18.00
” is shown in the Total Price display. Keep entering another
quantity as needed.
4. To end the By-Count function and return to normal weighing mode,
press [C].
4.10 Fractional Pricing (Version B)
If permitted by state law, and with Fractional Pricing enabled in the Service
Setup mode accordingly, press 100 g successively to price in
€ per 100 g,
return to normal Unit Price mode.
To enable Fractional Pricing in the Service Setup mode:
1.
Perform Step 1 in Section 6.1.
2.
“
S1 oFF
”
is displayed momentarily. Press [PLU] [5] [5] [5] [5] [5].
3.
“
SCL”
is displayed. Press [FIX].
4.
“
Step 1
” is displayed. Press [FIX] successively to move through
parameters Step 1 to 19*.
5.
When “
Step 19 oFF
” is displayed (this parameter enables 100g
pricing), press [>T<] to change the setting to “
on
”, then press [PLU] to
proceed to “
SAVE
”.