Parameter
Notation
Default
Value
Parameter Description
Range
BAUD
Baud rate of digital
communication
2
0
: 2.4 Kbits/s
1
: 4.8 Kbits/s
2
: 9.6 Kbits/s
3
: 14.4 Kbits/s
4
: 19.2 Kbits/s
5
: 28.8 Kbits/s
6
: 38.4 Kbits/s
ADDR
Address assignment of
digital communication
Low: 1
High: 255
COMM
Communication function
0
: No communication
1
: Modbus RTU mode protocol
1
2
:4-20mA retransmission output
3
:0-20mA retransmission output
:0-5V retransmission output
4
:1-5V retransmission output
5
:0-10V retransmission output
6
DATA
Data bit count of digital
communication
0
: 7 data bits
1
: 8 data bits
1
PARI
Parity bit of digital
communication
1
: Odd parity
2
: No parity bit
0
: Even parity
0
STOP
Stop bit count of digital
communication
1
: Two stop bits
0
0
: One stop bit
RELO
Retransmission low scale
value
Low: -19999
High: 45536
(0.0 °C)
32.0 °F
REHI
Retransmission high scale
value
Low: -19999
High: 45536
212.0 °F
(
)
100.0 °C
SEL1
Select 1'st parameter for
user menu
0
: No parameter selected
2
1
: LOCK is put ahead
2
: INPT is put ahead
3
: UNIT is put ahead
5
: SHIF is put ahead
6
: PB is put ahead
7
: TI is put ahead
4
: DP is put ahead
8
: TD is put ahead
11
: OFST is put ahead
12
: RR is put ahead
13
: O2HY is put ahead
10
: CYC1 is put ahead
9
: O1HY is put ahead
14
: CYC2 is put ahead
17
: ADDR is put ahead
15
: CPB is put ahead
16
: DB is put ahead
SEL2
Select 2'nd parameter for
user menu
3
Same as SEL1
SEL3
Select 3'rd parameter for
user menu
4
Same as SEL1
SEL4
Select 4'th parameter for
user menu
6
Same as SEL1
SEL5
Select 5'th parameter for
user menu
7
Same as SEL1
SEL6
Select 6'th parameter for
user menu
8
Same as SEL1
SEL7
Select 7'th parameter for
user menu
10
Same as SEL1
SEL8
Select 8'th parameter for
user menu
17
Same as SEL1
12