Power Input
Power Input
4: 90 - 250 VAC, 50/60 HZ
5: 11 - 26 VAC or VDC
4: 90 - 250 VAC, 50/60 HZ
5: 11 - 26 VAC or VDC
0: None
1: RS-485 interface
2: RS-232 interface
3: Retransmit
4-20 mA / 0-20 mA
4: Retransmit 1-5V /0-5V
5: Retransmit 0-10V
0: None
1: RS-485 interface
2: RS-232 interface
3: Retransmit
4-20 mA / 0-20 mA
4: Retransmit 1-5V /0-5V
5: Retransmit 0-10V
Communications
ETR-3000-
0: None
1: Form A relay 2A/240VAC
2: Pulsed voltage to
drive SSR, 5V / 30mA
3: Isolated 4 - 20mA / 0 - 20mA
4: Isolated 1 - 5V / 0 - 5V
5: Isolated 0 - 10V
6: Triac output, 1A / 240VAC, SSR
7: Isolated 20V/25mA transducer power
supply
8: Isolated 12V/40mA transducer power
supply
9: Isolated 5V/80mA transducer power
supply
C: Pulsed voltage to drive SSR,14V/30mA
0: None
1: Form A relay 2A/240VAC
2: Pulsed voltage to
drive SSR, 5V / 30mA
3: Isolated 4 - 20mA / 0 - 20mA
4: Isolated 1 - 5V / 0 - 5V
5: Isolated 0 - 10V
6: Triac output, 1A / 240VAC, SSR
7: Isolated 20V/25mA transducer power
supply
8: Isolated 12V/40mA transducer power
supply
9: Isolated 5V/80mA transducer power
supply
C: Pulsed voltage to drive SSR,14V/30mA
Output 2
Output 2
SNA10B = Smart Network Adaptor for ETR-Net
software, which converts 255 channels of
RS-485 or RS-422 to RS-232 network.
SNA10B = Smart Network Adaptor for ETR-Net
software, which converts 255 channels of
RS-485 or RS-422 to RS-232 network.
SNA10A = Smart Network Adaptor for third party
software, which converts 255 channels of
RS-485 or RS-422 to RS-232 Network.
SNA10A = Smart Network Adaptor for third party
software, which converts 255 channels of
RS-485 or RS-422 to RS-232 Network.
Related Products
Related Products
1-2 Ordering Code
1-2 Ordering Code
ETR-Set = Configuration Software
CC94-1 = RS-232 Interface Cable ( 2M )
CETR-9000-1 = Programming port cable for ETR-3000
ETR-Set = Configuration Software
CC94-1 = RS-232 Interface Cable ( 2M )
CETR-9000-1 = Programming port cable for ETR-3000
SNA12A = Smart Network Adaptor for programming
port to RS-232 interface
SNA12A = Smart Network Adaptor for programming
port to RS-232 interface
6
1: Standard Input
Thermocouple:J, K,
T, E, B, R, S, N, L
RTD: PT100 DIN,
Pt100 JIS
4: Linear voltage or
current such as
4-20mA (specify range)
1: Standard Input
Thermocouple:J, K,
T, E, B, R, S, N, L
RTD: PT100 DIN,
Pt100 JIS
4: Linear voltage or
current such as
4-20mA (specify range)
Signal Input
Signal Input
0: None
1: Relay rated
2A/240VAC
2: SSR Drive, 5V/30mA
3: Isolated 4 - 20mA / 0 - 20mA
4: Isolated 1 - 5V / 0 - 5V
5: Isolated 0 - 10V
6: Triac output 1A / 240VAC,SSR
C: SSR Drive,14V/30mA
0: None
1: Relay rated
2A/240VAC
2: SSR Drive, 5V/30mA
3: Isolated 4 - 20mA / 0 - 20mA
4: Isolated 1 - 5V / 0 - 5V
5: Isolated 0 - 10V
6: Triac output 1A / 240VAC,SSR
C: SSR Drive,14V/30mA
Output 1
Output 1
Display Color:
Display Color:
0: Red
(Standard)
1: Green
(Special Order)
0: Red
(Standard)
1: Green
(Special Order)