38
User Interface
User Interface
Single 4-digit LED Display
Programming Port :
Communication Port :
Keypad : 3 keys
For automatic setup, calibration and testing
Connection to PC for supervisory control
Single 4-digit LED Display
Programming Port :
Communication Port :
Keypad : 3 keys
For automatic setup, calibration and testing
Connection to PC for supervisory control
Control Mode
Control Mode
Output 1 :
Output 2 :
ON-OFF :
P or PD :
PID :
Cycle Time :
Manual Control :
Auto-tuning :
Failure Mode :
Ramping Control :
Reverse ( heating ) or direct ( cooling ) action
PID cooling control, cooling P band 50~300% of PB, dead band -36.0 ~ 36.0 % of PB
0.1 - 90.0 ( °F ) hysteresis control ( P band = 0 )
0 - 100.0 % offset adjustment
Fuzzy logic modified
Proportional band 0.1 ~ 900.0 °F.
Integral time 0 - 1000 seconds
Derivative time 0 - 360.0 seconds
0.1 - 90.0 seconds
Heat (MV1) and Cool (MV2)
Cold start and warm start
Auto-transfer to manual mode while sensor break or A-D converter damage
0 - 900.0 °F/minute or 0 - 900.0 °F/hour ramp rate
Output 1 :
Output 2 :
ON-OFF :
P or PD :
PID :
Cycle Time :
Manual Control :
Auto-tuning :
Failure Mode :
Ramping Control :
Reverse ( heating ) or direct ( cooling ) action
PID cooling control, cooling P band 50~300% of PB, dead band -36.0 ~ 36.0 % of PB
0.1 - 90.0 ( °F ) hysteresis control ( P band = 0 )
0 - 100.0 % offset adjustment
Fuzzy logic modified
Proportional band 0.1 ~ 900.0 °F.
Integral time 0 - 1000 seconds
Derivative time 0 - 360.0 seconds
0.1 - 90.0 seconds
Heat (MV1) and Cool (MV2)
Cold start and warm start
Auto-transfer to manual mode while sensor break or A-D converter damage
0 - 900.0 °F/minute or 0 - 900.0 °F/hour ramp rate
Digital Filter
Digital Filter
Function :
Time Constant :
First order
0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 seconds programmable
Function :
Time Constant :
First order
0, 0.2, 0.5, 1, 2, 5, 10, 20, 30, 60 seconds programmable
Approval Standards
Approval Standards
Safety : UL61010C-1
CSA C22.2 No. 24-93
CE EN61010-1 ( IEC1010-1 )
Safety : UL61010C-1
CSA C22.2 No. 24-93
CE EN61010-1 ( IEC1010-1 )
Environmental & Physical
Environmental & Physical
Operating Temperature :
Storage Temperature :
Humidity :
Altitude:
Pollution:
Insulation Resistance :
Dielectric Strength :
Vibration Resistance :
Shock Resistance :
Moldings :
Dimensions :
ETR-3000
Weight :
ETR-3000
-10 °
to 50 °
-40 °
to 60 °
0 to 90 % RH ( non-condensing )
2000m maximum
Degree 2
20 Mohms min. ( at 500 VDC )
2000 VAC, 50/60 Hz for 1 minute
10 - 55 Hz, 10 m/s for 2 hours
200 m/s ( 20 g )
Flame retardant polycarbonate
-----50mm(W) X 26.5mm(H) X 110.5mm(D), 98 mm depth behind panel
----- 120 grams
C
C
C
C
Operating Temperature :
Storage Temperature :
Humidity :
Altitude:
Pollution:
Insulation Resistance :
Dielectric Strength :
Vibration Resistance :
Shock Resistance :
Moldings :
Dimensions :
ETR-3000
Weight :
ETR-3000
-10 °
to 50 °
-40 °
to 60 °
0 to 90 % RH ( non-condensing )
2000m maximum
Degree 2
20 Mohms min. ( at 500 VDC )
2000 VAC, 50/60 Hz for 1 minute
10 - 55 Hz, 10 m/s for 2 hours
200 m/s ( 20 g )
Flame retardant polycarbonate
-----50mm(W) X 26.5mm(H) X 110.5mm(D), 98 mm depth behind panel
----- 120 grams
C
C
C
C
2
2
Protective Class :
EMC:
Ip65 front panel
CE En61326
Protective Class :
EMC:
Ip65 front panel