12.0
2
ANOMALIE
CAUSE
RIMEDI
The plates do not heat
themselves or do not heat
enough
By pushing the cycle starting
button the lower plate does
not move itself
During the pressing
operation the dough sticks
to the plates
At the ending of the pressing
operation the dough is
slightly cooked
At the end of the pressing
operation the dough has not
the width desired
1. The resistors are damaged
2. The resistors electric
contacts are damaged
3. The thermostat are set with
a low temperature
1. The drive belt of the
movement to the pulley is too
slow
2. The drive belt of the
movement to the pulley is
broken
3. The button does not make
contact because of the flour
and the dust
1. Plates temperature is too
low
2. The plates are dirty
3. Particularly sticky dough
1. Plates temperature is too
high
2. Plates closing time is too
long
1. The distance between the
plates is not correct
2. Plates closing time is not
correct
1. Replace the resistors
2. Reset the resistors electric
contacts
3. Reset thermostat tempera-
ture
1. Adjust belt stress
2. Replace the belt
3. Clean the start button
1. Adjust plates temperature la
(>120°C) by the the relative
thermostats
2. Clean the plates
2. Flour the rounded dough
1. Adjust plates temperature
by the relative thermostats
2. Shorten plates closing time
by adjusting the timer
1. Regulate the distance
between the plates by a
feeler
2. Adjust plates closing
time by a timer
Содержание PIZZAFORM
Страница 38: ......
Страница 74: ......
Страница 110: ......
Страница 146: ......
Страница 182: ......
Страница 183: ...OEM ALI Group S r l a Socio Unico Viale Lombardia 33 46012 BOZZOLO MN Italia Tel 39 0376 910511 Fax 39 0376 920754...
Страница 184: ......
Страница 185: ......
Страница 193: ......
Страница 194: ...Cod OMMI045TN Rev 01 del 06 2018...