INPUT Setting Commands
Command for using basic function of load with PC Remote Interface.
INPUT {ON | OFF}
Command for controlling INPUT ON / OFF of load.
>ON
Able Input
>OFF
Disable Input
ex1) input on
Able Input
ex2) input off
Disable Input
INPUT ON?
Command for checking load's input status.
Return value
"0"
Disable the input status.
"1"
Able the input status.
MODE:{CC | CV | CR |CP |ONOFF | FUSE | BAT }
Command for setting load's mode.
>MODE:CC
CC Mode(Constant Current)
>MODE:CV
CV Mode(Constant Voltage)
>MODE:CR
CR Mode(Constant Resitstance)
>MODE:CP
CP Mode(Constant Power)
>MODE:ON/OFF
ON/OFF Mode(Constant Current ON/OFF test)
>MODE:FUSE
FUSE Mode(Constant Voltage test)
>MODE:BAT
BAT Mode(Battery test)
MODE?
Command for checking load's mode status.
Return value
"CC"
CC Mode
Return value
"CP"
CP Mode
"CV"
CV Mode
"ON/OFF" ON/OFF Mode
"CR"
CR Mode
"FUSE"
FUSE Mode
"BAT"
BAT Mode
RANG{0~3}
Command for changing load's CC/CV range.
0:CC.H_CV.H 1:CC.L_CV.H 2:CC.H_CV.L 3:CC.L_CV.L
RANG?
Command for changing confirmation of load's CC/CV range.
CURR {value}
Command for setting input value of CC Mode. (Only available on CC Mode)
>value
Input current value.
ex) curr 10
Set current as 10A
- 86 -