This is the setting key to configure your electronic load for RS-232C, RS-485, TCP/IP(option).
You have to set your electronic load before remote interface.
The default setting is RS-232C protocol and baud rate is 9600bps.
communication setting is only able to be set by front panel key.
▌IO/LOCAL setting is stored permanentely until you change it in non-volatile memory,
even if you turn off your power supply.
▌Once remote interface works, the RMT lamp on the front panel lights up and remote device
will be controlled preferentially.
▌To control the electronic load on local mode, finish remote interface and press “IO/LOCAL Key”.
Then RMT lamp will lights off and you can control your E-Load on the front panel.
(If you can't control the load though RMP lights off, please check if the load is under KEY LOCK state.)
RS-232C SET
To set up RS-232C, proceed as follows.
▌Power ON
▌INPUT is off (ON icon lights off)
▌Enter IO/LOCAL menu
▌Press IO/Local Key to set RS-232C
▌RS-232C menu setting
Move to RS-232C menu by using left/right key
When in RS-232C menu, "1. RS-232C" is displayed on 2nd line of LCD
※IO/LOCAL menu order: 1.RS-232C ↔ 2.RS-485 ↔ 3.TCP/IP
▌Entering RS-232C Baud Rate
▌Press IO/Local Key to set Baud Rate.
▌To set RS-232C Baud Rate,
press left/right key to Baud Rate you want to change.
※RS-232C Baud Rate order: BR_1: 9600BPS ↔ BR_2: 19200BPS ↔
BR_3: 38400BPS ↔ BR_4: 57600BPS ↔ BR_5: 115200BPS
▌Saving RS-232C communication setting
Press IO/Local key.
After saving RS-232C setting,
exit Remote interface setting menu and return to Manual mode.
Note
What is the 'BPS'? BPS is the short word for Bit per Second.
It is the unit that means it can transfer 1bit/sec and higher unit means higher transfer speed.