PIA-982043-AIR FALCON-T200-in-EN | www.ochsner.com 43
Electrical connection
Material damage
An external source of voltage at the sensor termi-
nals can destroy the OTS controller.
»
Ensure that no 230 VAC or 400 VAC cables
are touching the sensor terminals on the OTS
controller.
WARNING: Electrocution
When the appliance power supply is on, there will
always be 230 VAC at the PSU signal contact.
»
Route the cable through the appliance from the back.
1 Cable entry at the back of the appliance
2 Cable conduit through the appliance
3 Cable outlet into the control box
»
Connect the bus cable between the indoor and out-
door units to the terminals provided.
»
Connect the temperature sensor required for your
system to the corresponding terminals.
»
Connect the external pumps and servomotors re-
quired for your system (3-way switching module,
mixing valve) to the terminals provided.
»
Connect the power supply cable for the controller
supply.
»
Connect the power supply for the electric auxiliary
heater.
Temperature sensor
Abbreviations
Description
T-AU
Outdoor temperature
T-HK2
Flow temperature heating circuit
Communication
Abbreviations
Description
Smart grid
Smart grid
BUS
KNX connection
Room temperature sensor
WQA-BUS
Heat source system bus
Connection between indoor and
outdoor unit
Содержание AIR FALCON 212 C11A T200
Страница 2: ...2 www ochsner com PIA 982043 AIR FALCON T200 ih EN...
Страница 7: ...PIA 982043 AIR FALCON T200 sh EN www ochsner com 7 Safety...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 13: ...00_200_202_08_02_002 EN www ochsner com 13 Device description...
Страница 31: ...00_200_202_08_01_002 EN www ochsner com 31...
Страница 47: ...PIA 982043 AIR FALCON T200 in EN www ochsner com 47...
Страница 51: ...00_400_01_01 EN www ochsner com 51...
Страница 64: ...64 www ochsner com PIA 982043 AIR FALCON T200 td EN Dimensions and connections 20 2 1 Drainage plug...
Страница 65: ...PIA 982043 AIR FALCON T200 td EN www ochsner com 65...
Страница 67: ...PIA_982043_AIR_FALCON_T200_EN06 1 www ochsner com 67...