PLEASE NOTE
►
Connection to the mains electricity supply must be
by means of a fixed connection.
It must be possible
to isolate the appliance from the mains supply with
a multi pole switch which has a gap of at least 3 mm
across all poles.
►
You must not disconnect the power supply even if
heating is not required. If the power supply is discon-
nected, active frost protection of the system cannot
be guaranteed.
►
Observe the minimum clearances in order to ensure
fault-free operation of the appliance and to allow for
maintenance work on the appliance.
►
Maintenance work such as checking the electrical
safety of the appliance may only be carried out by a
qualified contractor.
►
We recommend an annual inspection (to assess the
appliance‘s actual state) and if necessary any main-
tenance (to reinstate it to its expected state) by a
qualified contractor.
►
We guarantee trouble-free function and operational
reliability only if the original accessories and spare
parts intended for the appliance are used.
►
Observe all applicable national and regional regula-
tions and provisions.
►
The appliance is fitted with an electric auxiliary heat
-
er. The auxiliary heater is not normally switched on
until the bivalent point is undershot. In exceptional
cases the auxiliary heater may also switch on irre-
spective of the bivalent point:
- The auxiliary heater switches on if the heat
pump is not enabled as the heat generator.
This can happen if there is a fault or the limits
of use have been exceeded.
- The auxiliary heater switches on if more output
is required than the heat pump can provide.
This can happen if the heat pump is already
close to reaching the limits of use.
1. Information on documentation
This documentation is aimed at qualified contractors and
specialist design engineers. It is not intended for use by
appliance operators.
Unless otherwise stated, all content of this documentation
applies to the following appliances:
Appliance
Article number
AIR FALCON 212 C11A T200
286700
AIR FALCON 212 C11B T200
286710
AIR FALCON 212 C11B T201
286720
This documentation describes appliances that are not al-
ways in the standard scope of delivery. Therefore there
may be differences to your specific appliance.
Note
Read all of this documentation carefully before us-
ing the appliance and keep the documents safe.
Pass this documentation on to any new user.
Note
A separate operating manual is available for op-
erating the system. This also includes the ERP
data. This document is attached to the machine
in printed form or can be found in digital form on
the OCHSNER homepage in the download area.
1.1 Safety information
1.1.1 Arrangement of safety information
KEYWORD: Type of risk
The possible consequences of not observing the
safety information are shown here.
»
Instructions for action to remedy or remove
the source of danger are shown here.
1.1.2 Symbols and possible dangers
Symbol
Type of risk
Injury
Electrocution
Burns
(burns, scalding)
Material damage
(appliance, consequential and environmental dam-
age)
Содержание AIR FALCON 212 C11A T200
Страница 2: ...2 www ochsner com PIA 982043 AIR FALCON T200 ih EN...
Страница 7: ...PIA 982043 AIR FALCON T200 sh EN www ochsner com 7 Safety...
Страница 9: ...00_400_200_202_01_split_Funktionsweise EN www ochsner com 9 How split systems work...
Страница 13: ...00_200_202_08_02_002 EN www ochsner com 13 Device description...
Страница 31: ...00_200_202_08_01_002 EN www ochsner com 31...
Страница 47: ...PIA 982043 AIR FALCON T200 in EN www ochsner com 47...
Страница 51: ...00_400_01_01 EN www ochsner com 51...
Страница 64: ...64 www ochsner com PIA 982043 AIR FALCON T200 td EN Dimensions and connections 20 2 1 Drainage plug...
Страница 65: ...PIA 982043 AIR FALCON T200 td EN www ochsner com 65...
Страница 67: ...PIA_982043_AIR_FALCON_T200_EN06 1 www ochsner com 67...