APPENDIX C: ORDERING CODE
DIAM4200 PART NUMBER IDENTIFICATION (
OLD CODE, UP TO 2018
)
The DIAM4200 regulator is identified by a serial ordering number which indicates its type and particularity. If needed, add all useful precision
and options.
Example : D42-IEC-1-5-50-15-400-B21-530 = DIAM4200 compliant to IEC, 6.6A, 5 brightness, 50Hz, 15kVA, 400Vac, with a multiwire
interface (dry contacts) ,Jbus serial network, lightning arrestors on output terminals, Circuit breaker, EFD and LFD
D 4 2 - I E C - 1 - 5 - 5 0 - 1 5 - 4 0 0 - B 2 1 - 5 3 0
D42: DIAM 4200
IEC: IEC type
828: L-828 FAA Type (Options as described in L828 advisory are included)
829: L-829 FAA Type (Options as described in L829 advisory are included)
AXX : AENA compliance (A29 = AENA PPT2-1995; A04 = AENA PPT2/04/04-2004
1:
Class1 (output current 6.6A)
3:
Style 1 (Class1 : 4.8A, 5.5A, 6.6A)
5:
Style 2 (Class1 : 2.8A, 3.4A, 4.1A, 5.2A, 6.6A)
A : 5 brightness, AENA values
X: Number of brightness, up to 8 (not
counting B0 = “black” current) : Values of currents must be specified separately
50: 50 Hz
60: 60Hz
01: 1kVA
05: 5kVA
15: 15kVA
02: 2.5kVA
07: 7.5kVA
20….20KVA
04: 4kVA
10: 10kVA
XXX: Input voltage :For power up to 2,5KVA: 220, 230, 240, 380, 400, 415 Vrms
For power from 5KVA to 15KVA: 230, 400 Vrms
0X : No multiwire interface
00X : No multiwire interface
XX0 : No communication network
AX : INTERNAL source Remote control
A1X or B1X : NEGATIVE common
monitoring (IEC interface board)
XX1 : 1 x JBus RS485 port
BX : EXTERNAL 20 to 60 Vdc Rem. Control
A2X or B2X: free common monitoring
(FAA interface board, dry contacts)
XX2 : 2 x Jbus RS485 ports
CX : AENA terminal block
C2X
XX3 : 1 x Lonwork port
DX : Cylindrical sockets (SOURIAU)
D2X
XX4 : 1 x Ethernet port
GX : INTERNAL 120Vac remote control
G2X
XX5 : 1 x Jbus and 1 x Ethernet ports
HX : EXTERNAL 120Vac remote control
H2X
XX6 : 2 x Ethernet ports
XX7 : 1 x Lonwork port + 1 x JBus
RS485 port
(Only one letter must be selected)
(Only one figure must be selected)
(Only one figure must be selected)
0XX : No extra protection options,
X0X : No extra monitoring options,
XX0 : No extra options
1XX : Lightning arrestors (outputs)
X1X : Earth Fault Detector (EFD)
XX1 : Cut-out / earthing jumpers
2XX : Lightning arrestors (inputs)
X2X : Lamp Failure Detector (LFD)
XX2 : Casters (unidirectional)
4XX : Circuit Breaker (see Note 1)
X4X : Time meters (each brightness) XX4: ECB option included
(Final number : add all needed weights)
(Final number : add all needed
weights)
(Final number : add all needed
weights)
Other Options : ICSx (Integrated Circuit selector x-ways)
Or specify : (FAA cut-out, IP other than IP21...)
Note 1 : Circuit breaker
is not optional
and always included in D42 CCR family, whatever the choice 4 (compatibility of the part number with
other CCR family)
Serie
s
Freq.
Supply
Output
power
Type
Class
Style
Regular
Options
Control