II.1.3 DEVICE LOCATION
In deciding the permanent operating location for the device, the following points must be kept in mind:
▪
An easy access must be kept to the front door with no obstruction.
▪
CCRs can be placed side-by-side, or stacked one on top of the other.
▪
Leave a 20cm gap at least at the back of the device to allow sufficient ventilation
▪
Environmental conditions must be such that the temperature does not go outside the range -20°C to
+55°C and that relative humidity does not exceed a maximum of 95%.
▪
The location m
ust be compatible with the “IP20” protection index of the CCR.
II.1.4 STACKING DEVICES
The cabinet of DIAM3100 is designed to be stacked (3 units maximum).
In order to achieve that disposition, frames have to be prepared as following :
1. All CCRs :
▪
Remove the two lifting rings, and the top roof
▪
Fit and fix the CCR at its place
2. Upper CCRs :
▪
Remove the four casters
▪
Put the upper CCR onto the lowest, and fix it by means of screws (using the
roller’ screws) :