Alarms and Warnings:
Alarm : (the CCR failed to supply the load); for example, the CCR is stopped by a loop open circuit :
Cancel fault(s)
Warning :
(the CCR doesn’t stop; warning is only indicative); It is the case for EFD and LFD faults.
Alphanumeric display:
VFD display (16 x 140 pts) : upper text provide data information, and lower text the key definition.
Screen saver : The brightness decreases automatically or turn off after one hour if the keyboard is not used.
Turns on again instantly when a key is pressed. (Function user-definable)
Rx: indicator Data reception on ETHERNET connection
Tx: indicator Data transmission on ETHERNET connection
Rx
Tx
I.4.2 CONTROL
The device is controlled by mean of a 4 buttons on the keypad which allows to change the operating mode:
“Stop” – Manual or “Local” mode – Remote or “Auto” control mode.
•
Stop mode:
In that mode, “Stop” is highlighted. The CCR stops, whatever the current brightness orders (remote control or
local selection).
Menus can then be accessed.
•
Local mode:
In that mode appears brightness controls : The brightness is chosen by pressing buttons
B-
and
B+
(from B0 to
B7 maximum, according to the number of brightness levels configured).
•
Remote control mode:
In that mode, “Auto” is highlighted. Operation of the CCR is controlled the serial network.
See paragraph I.5.2 to adjust brightness current and protection levels.
ALARM: I<<Open Cir.
reset
Io:0.00A STOP
stop
local
auto
menu
Io:6.60A <B5>
stop
B-
B+
menu
Io:0.00A <-->
stop
local
auto
menu
Io:5.20A <B4>
stop
local
auto
menu
Содержание AUGIER energy DIAM3100 Series
Страница 2: ...DIAM3100 2012 AUGIER SA I 2...
Страница 6: ...DIAM3100 2012 AUGIER SA I 6...
Страница 13: ...DIAM3100 2012 AUGIER SA I 13 I 2 4 DIMENSIONS...
Страница 14: ...DIAM3100 2012 AUGIER SA I 14 Stacked CCRs...
Страница 28: ...DIAM3100 2012 AUGIER SA I 28...
Страница 56: ...DIAM3100 2012 AUGIER SA V 56 V APPENDIX A DIAGRAM...