- English -
9
Cleaning the quartz glass / Replacing the UVC lamp
Attention! Ultra-violet radiation.
Possible consequences:
Eye or skin injury from burns.
Protective measures:
•
Never operate the UVC lamp outside its housing.
•
Never operate the UVC lamp in a housing that is defective.
Attention!
Breakable glass.
Possible consequences:
Injury to your hands caused by cuts.
Protective measures:
Handle the quartz glass and UVC lamp with care.
Note!
For safety reasons the UVC lamp can only be switched on when the unit head has been correctly fitted into
the casing.
Opening the UCV clarifying unit
F
•
Remove the cover from the UVC clarifying unit.
•
Turn the UVC clarifying unit counter-clockwise up against the stop (bayonet closure), then carefully pull out of the
filter cover including the O ring (1).
•
Loosen the self-tapping screw (7) until the the screw tip is sunk in the housing of the clamping screw (2).
•
Unscrew the clamping screw counter-clockwise (3).
•
Remove the quartz glass including the O ring towards the front with a slight turning movement (4).
•
Check the quartz glass and the O ring for damage and replace, if necessary.
•
Clean the quartz glass outer face with a moist cloth.
Replacing the UVC lamp
F
Important:
Only use lamps the identification and capacity data of which correspond to the information on the type
plate.
For an optimum filter performance, we recommend to replace the UVC lamp after approx. 8,000 operating hours.
•
Pull out and replace the UVC lamp.
Assembly of
the UVC clarifying unit
F
•
Insert the quartz glass including the O ring against the stop in the unit head (6).
•
Press the O ring into the gap between unit head and quartz glass.
•
Tighten the clamping screw clockwise up to the stop (7).
•
Tighten the self-tapping screw (8).
•
Check the O-Ring at the unit head for damage and replace, if necessary (9).
•
Carefully push the unit head into the housing while applying slight pressure. Ensure that the tenons at the housing
engage in the grooves of the bayonet closure.
•
Turn the unit head clockwise against the stop while applying slight pressure.
•
Refit the cover for the UVC pre-clarifying unit.
40370-09-14_GA_BioPress 1600_USA9 9
18.09.2014 11:19:25
Содержание BioPress 1600
Страница 2: ...2 BPS0001 40370 09 14_GA_BioPress 1600_USA2 2 18 09 2014 11 19 21...
Страница 3: ...3 A BPS0003 B BPS0017 C BPS0005 40370 09 14_GA_BioPress 1600_USA3 3 18 09 2014 11 19 21...
Страница 4: ...4 D BPS0007 E BPS0009 40370 09 14_GA_BioPress 1600_USA4 4 18 09 2014 11 19 22...
Страница 5: ...5 F BPS0014 40370 09 14_GA_BioPress 1600_USA5 5 18 09 2014 11 19 24...
Страница 22: ...22 BPS0013 40370 09 14_GA_BioPress 1600_USA22 22 18 09 2014 11 19 25...
Страница 23: ...40370 09 14_GA_BioPress 1600_USA23 23 18 09 2014 11 19 26...