NXP Semiconductors
UM11729
FRDMGD3162HBIEVM half-bridge evaluation board
4.4.3 Power supply and jumper configuration
Figure 5. Power supply and jumper configuration
Jumper
Position
Function
1-2
dead time fault protection enabled (high side)
PWMHSEL (J10)
2-3
dead time fault protection disabled (use for short-circuit testing)
1-2
dead time fault protection enabled (low side)
PWMLSEL (J14)
2-3
dead time fault protection disabled (use for short-circuit testing)
open
VCCREG controls gate voltage
VCCH and VCCL
closed
VCC and VCCREG are tied together
1-2
chip select for normal operation
CSB (J7)
2-3
chip select for daisy chain operation
closed
normal operation
MOSI (J11)
open
daisy chain operation
1-2
normal operation
MISO (J9)
2-3
daisy chain operation
Table 4. Jumper definitions
UM11729
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2022. All rights reserved.
User manual
Rev. 1 — 21 February 2022
11 / 43