UM10147_2
© NXP B.V. 2008. All rights reserved.
User manual
Rev. 02 — 28 April 2008
73 of 134
NXP Semiconductors
UM10147
P89LPC952/954 User manual
The values for I2SCLL and I2SCLH do not have to be the same; the user can give
different duty cycles for SCL by setting these two registers. However, the value of the
register must ensure that the data rate is in the I
2
C data rate range of 0 to 400 kHz. Thus
the values of I2SCLL and I2SCLH have some restrictions and values for both registers
greater than three PCLKs are recommended.
11.6 I
2
C operation modes
11.6.1 Master Transmitter mode
In this mode data is transmitted from master to slave. Before the Master Transmitter mode
can be entered, I2CON must be initialized as follows:
CRSEL defines the bit rate. I2EN must be set to 1 to enable the I
2
C function. If the AA bit
is 0, it will not acknowledge its own slave address or the general call address in the event
of another device becoming master of the bus and it can not enter slave mode. STA, STO,
and SI bits must be cleared to 0.
Table 69.
I
2
C clock rates selection
Bit data rate (Kbit/sec) at f
osc
I2SCLH
CRSEL
7.373 MHz
3.6865 MHz 1.8433 MHz 12 MHz
6 MHz
6
0
-
307
154
-
-
7
0
-
263
132
-
-
8
0
-
230
115
-
375
9
0
-
205
102
-
333
10
0
369
184
92
-
300
15
0
246
123
61
400
200
25
0
147
74
37
240
120
30
0
123
61
31
200
100
50
0
74
37
18
120
60
60
0
61
31
15
100
50
100
0
37
18
9
60
30
150
0
25
12
6
40
20
200
0
18
9
5
30
15
-
1
3.6 Kbps to
922 Kbps
Timer 1 in
mode 2
1.8 Kbps to
461 Kbps
Timer 1 in
mode 2
0.9 Kbps to
230 Kbps
Timer 1 in
mode 2
5.86 Kbps to
1500 Kbps
Timer 1 in
mode 2
2.93 Kbps to
750 Kbps
Timer 1 in
mode 2
Table 70.
I
2
C Control register (I2CON - address D8h)
Bit
7
6
5
4
3
2
1
0
-
I2EN
STA
STO
SI
AA
-
CRSEL
value
-
1
0
0
0
x
-
bit rate