Section 11
System Cleaning, Maintenance and Reinstallation
Cocoon Aqua IR Hydration Pro System
50
11.6.2: Aroma System Deep Cleaning
Recommended to be completed once per week:
1. Turn the system on by pressing the
On/Off
button located at right side of head of system.
2. Press
Enter
on the LCD panel to continue.
3. Enter the service menu by using the directional arrows until
Service
feature is
highlighted.
4. Scroll down to
Aroma Cup
feature until highlighted.
5. Press the right arrow to open the
Aroma Cup
feature. You may hear a faint clicking
sound as drainage opens.
6. Let all aroma oil drain completely from the unit.
7. Look under the left foot end leg to locate the aroma tank.
8. Grasp the red connection on the end of the wire, pull away from valve. Gently unplug the
two wires that lead to the aroma valve.
9. With one hand hold the white plastic valve seat that is attached to the gray bottle cap.
With the other hand grasp the valve and twist a quarter turn clockwise.
10. Wiggle the valve to loosen and pull down and remove.
11. Use some alcohol to clean the black rubber stopper on the valve.
12. Use alcohol to clean the valve seat.
13. Reinstall the valve by inserting the valve into the seat and turning counter clockwise.
14. Reconnect the two wires that lead to the aroma valve.
11.7 Cleaning the System Drain (located under the upper vibratory bed)
Recommended to be completed nightly:
1. Carefully unplug the upper and lower vibration beds. The plugs must be unlocked
counterclockwise before removing male from female connectors.
2. Remove the bed section and set off to the side of the machine.
3. Use Accel disinfectant and dry towel to wipe the drain clean. A small, soft brush (i.e. a
nail brush) may be helpful.
4. Place a catch pan under the nipple under the foot end of the unit.
5. Pour a half-gallon of hot tap water down the drain to flush it out.
6. Reinstall the upper and lower vibration beds by placing the molded bed supports onto the
bed balls. Gently replace and relock the vibration bed connectors.
Note:
Tap water can be used for this process & an ounce of Accel solution can be added
to the water if so desired.
11.8 Annual Maintenance and Periodic Inspections
IR Emitters Check
o
Do all 3 IR emitters warm up?
o
Does each IR emitter have a proper and functional protective flock IR cover?