Section 10
Advanced Electronics and Troubleshooting
Cocoon Aqua IR Hydration Pro
44
10.3 Troubleshooting
Always try to restart the capsule before any troubleshooting.
LCD Display Error Messages
Message
Trigger
Probable Cause
Corrective Action
System damage!
Data communication between
upper PC board (LCDrx) and
lower PC board (Rabbit) is
loose
Plug is loose
Check the plug connections
between upper and lower PC
boards
Capsule is blocked
Press ON/OFF switch. If you don’t
hear the characteristic noise inside
the right panel see “On
-
off Switch”
HOOD OPEN!
Hood opening
Plug is loose
Check the plug between
magnetic switch and PC board
Faulty magnetic switch
See “Hood Switch”
READY
Warm-up program is
finished properly
-
Press ENTER to selections
NOT READY
Warm-up program is
currently running (7min)
Warm-up program did not finish
Press ESCAPE to get back
to MAIN MENU
Restart the Cocoon Aqua IR
Hydration Pro
using ON/OFF switch
NO INCOMING WATER!!!
Cocoon Aqua IR Hydration Pro
steam generator did not get the
water during 15 sec from
injection valve opening
Wall faucet is closed
Open wall faucet
Generator filling valve faulty
Check valve 29 connections and
power
Water pressure loss
Check the water filter for proper
operation
WATER TANK EMPTY!!!
Cocoon Aqua IR Hydration Pro
steam generator did not get the
water during 25s from injection
valve opening
Wall faucet is closed
Open wall faucet
Generator filling valve faulty
Check valve 29 connections and
power
Water pressure loss
Check the water filter for proper
operation
HEATER
COMBUSTION!!!
(Heater fault)
The steam generator
thermal fuse is blown
Thermal fuse is blown
See “Replacing the Thermal Fuse”.
Check the heating element too - it
may be damaged as well
ADD UP TO 300ml
AROMA LIQUID!
Aroma tank is empty
Aroma tank is empty
Add aroma liquid
Level sensor adjustment
of sensitivity
Adjust the sensitivity level sensor
See “Aroma System”
Level sensor plug is loose
See “Aroma System”
Level sensor wrong position
See “Aroma System”
Level sensor faulty
See “Aroma System”
FILL THE WATER TANK!
Cocoon Aqua IR Hydration Pro
steam generator does not have
enough distilled water to start
the steam session
Don’t have enough water
Add distilled water
Upper level sensor
plug is loose
Check the connection between
sensor and PC board
Upper level sensor faulty
See “Replacing the Water Level
Se
nsor”