![NuAge Beauty COCOON AQUA IR HYDRATION PRO Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/nuage-beauty/cocoon-aqua-ir-hydration-pro/cocoon-aqua-ir-hydration-pro_owners-manual_1715629049.webp)
Section 10
Advanced Electronics and Troubleshooting
Cocoon Aqua IR Hydration Pro
45
Message
Trigger
Probable Cause
Corrective Action
WATER TANK FULL!
Cocoon Aqua IR Hydration Pro
steam
generator is full
Water tank is full
Do not add water
Start the steam session
Water level sensor(s)
plug is loose
Check the connection between
Sensor and PC board
STEAM ACTIVATING ON MENU IS OK BUT NO STEAM
Thermal fuse is blown
Check the heating element too - it
may be damaged as well. See
“Replacing the Thermal Fuse” and
“Replacing the Water Level
Sensor”
Hood is open
Close hood
Water level sensor(s)
plug is loose
Check the connection between
Sensor and PC board
Water level sensor(s) faulty
See “Replacing the Thermal Fuse”
and “Replacing the Water Level
Sensor”
Heating element is burned
See “Replacing the Heating
Element”
VIBRATORY B
ED DOESN’T FUNCTION
Plug is loose
Check plug connection under the
vibratory bed
Motor short circuit
See “Vibratory Bed”