6.9 Installation Test
Upon installation perform the checks listed below:
1.
Ensure there is power to the display.
2.
At the top of the
display will be the message “Blocking Keyboard” this means that there
is no function of the control panels until there is time set on the T Max 3A timer and it is
activated.
3.
Press the up arrow on the T Max 3A timer to set 30 minutes on the timer.
4.
Press the Enter button on the timer to start.
5.
The message “Blocking Keyboard” should go away.
6.
Slowly add distilled water to the unit until there is a beep and the "FILL TANK WITH
DISTILLED WATER" message goes away.
7.
Initial Warm-Up will start once tank is filled with water.
8.
Open Hood to cancel out the initial Warm-Up.
9.
Welcome Screen displays. Press ENT to continue.
10.
Highlight the “Programs” option and press Enter
11.
Highlight “Program #4
-
Custom” and press Enter.
12.
Highlight the “Vibration” option and press Enter. Inspec
t both the upper and lower bed
sections to ensure they are in working order.
13.
Highlight the “Radiant Heat” option and press Enter. Select the “High” setting and press
Enter. Allow running for approximately 5 minutes and very carefully tapping the back of
each heater housing to confirm that they are in working order.
14.
Turn off the “Radiant Heat” option.
15.
Highlight the “Temperature” option and press Enter. Use the Right Arrow to adjust the
steam to 118 degrees Fahrenheit. Ensure that the unit reaches 118 degrees in about 5
minutes.
16.
Perform an initial run of all functions before installing the “Right Side Panel” and “Hood
Cover.”