![NuAge Beauty COCOON AQUA IR HYDRATION PRO Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/nuage-beauty/cocoon-aqua-ir-hydration-pro/cocoon-aqua-ir-hydration-pro_owners-manual_1715629026.webp)
Section 7
Operation
Cocoon Aqua IR Hydration Pro System
22
maximum efficiency of steam production during Cocoon Aqua IR Hydration Pro programs,
ensuring the unit is warmed inside efficiently for maximum client comfort whether it is for the first
client of the day, running sessions back to back or the unit is idle ( not in use) during the day.
The Automatic Warm-Up programs will never interrupt the use of a standard program (Prepare,
Prolong, Protect, Customized). If for any reason the Automatic Warm-Up program is running
when a client is preparing to use, the user simply opens the hood or presses ESC to interrupt
the warm-up session and can immediately proceed with their treatment.
Please see Table 1 below for each preprogrammed warm-up functions compositions,
preconditions and system responses.
Warm Up Functions
System Preconditions
and Responses
INITIAL WARM UP
AUTOMATIC WARM UP
MANUAL WARM UP
Preconditions to start
Hood must be closed and
steam generator must be
filled with water
Hood must be closed and
steam generator must be
filled with water
Hood must be closed
and steam generator
must be filled with
water
Start time
Starts at 3 minutes after
machine is turned ON.
Starts
every time the unit
is filled with new water
and 60 minutes after last
session has ended.
Starts manually when
selected from the
MAIN MENU.
Special start time
If the steam generator is
empty and the steam
generator is filled in less
time then 3 minutes then
the WARM UP starts
immediately.
If unit is
idle
Automatic
Warm up starts every 60
min to keep steam
generator
warm.
none
Duration of the program
10 minutes Total Time ( 5
min steam generator
heating & 10 min infrared
elements)
5 minutes Total Time ( 3
min steam generator
heating & 5 min infrared
elements)
5 minutes Total Time (
5 min steam generator
heating & 5 min
infrared elements)
T-Max dependency
Not dependent
Not dependent
Can not be started if T-
Max block message is
shown. Must start
TMAX to have access
to control panel
Program termination by
user intervention by lifting
the hood
WARM UP is terminated
and WELCOME SCREEN
is displayed
WARM UP is terminated
and WELCOME
SCREEN is displayed
WARM UP is
terminated and
WELCOME SCREEN
is displayed
Program termination by
user intervention by
pressing ESC on the key
pad
Questions to User: "DO
YOU WANT TO STOP?" IF
YES PRESS ENT. IF NO
PRESS ESC.
Questions to User: "DO
YOU WANT TO STOP?"
IF YES PRESS ENT. IF
NO PRESS ESC.
Questions to User: "DO
YOU WANT TO
STOP?" IF YES
PRESS ENT. IF NO
PRESS ESC.
Program termination by
user intervention by
pressing ENT on the key
pad
WARM UP is terminated
and WELCOME SCREEN
is displayed
WARM UP is terminated
and WELCOME
SCREEN is displayed
WARM UP is
terminated and
WELCOME SCREEN
is displayed
TABLE 1