![NSK Megatorque PS Series Скачать руководство пользователя страница 286](http://html.mh-extra.com/html/nsk/megatorque-ps-series/megatorque-ps-series_user-manual_1714650286.webp)
— 9-62 —
Ì
SQ: (Factory use only)
This parameter is for the factory use only. Do not change the setting. .
SU: (Factory use only)
This parameter is for the factory use only. Do not change the setting. .
SV:
Servo
on
The command SV allows the System to activate the Motor servo. The input SVON (Servo on)
controls on and off of the Motor servo.
◊
Refer to “7.1.4. Servo on: SVON” for details.
◊
The command MO (Motor off) deactivates the Motor servo and prohibits activating the
Motor servo afterward.
Category Command
Format
SV
SW: Saw Wave
This monitor outputs a saw wave to the monitors MON1 and MON2.
Category Monitor
Format
SW
Data range
– 128 to 127
For an example, set the parameter MN (Primary analog monitor) to “MNSW” for testing the
primary analog monitor.
◊
The monitor outputs the saw wave of which frequency is 256 [ms] and output level is 0
to 5 [V].
Figure 9-8: Example of the analog monitor SW
Dispalay of an Oscilloscope
256 [ms]
0 [V]
5 [V]