— 8-19 —
8.3.2.2. Velocity: Outputs TVU (Velocity, Under) and TVO (Velocity, Over)
Outputs the condition of velocity against the threshold.
The outputs can be used to confirm if the Motor is stopping.
Table: 8-18: Prameter related to the outputs TVU and TVO
Parameter
(code)
Function
Initial
setting
Data Range
Unit
TVU
Threshold: Velocity under
0.000
0.000 to 10.000
s
-1
TVO
Threshold: Velocity, over
0.000
0.000 to 10.000
s
-1
The output TVU closes when the absolute value of velocity is less or equal to the set value.
The output TVO closes when the absolute value of velocity is greater or equal to the set value.
8.3.2.3. Torque Command: Outputs TTU (Torque Command, Under) and TTO (Torque Command,
Over)
Outputs the condition of torque command against the threshold.
Table 8-19: Parameter related to the outputs TTU and TTO
Parameter
(code)
Function
Initial
setting
Data Range
Unit
TTU
Threshold: Torque command, under
0.00
0.00 to 100.00
%
TTO
Threshold: Torque command, over
0.00
0.00 to 100.00
%
The output TTU closes when the absolute value of torque command is less or equal to the set
value. The output TTO opens when the absolute value of torque command is greater or equal to
the set value.