— 7-34 —
7.4. Analog Monitors
You may monitor the internal state of the Driver Unit by the outputs of MON1 and MON2
(Analog monitor) on the front panel.
The contents of the monitors are broadly classified into the following two categories.
◊
Nine types of preset monitor
◊
Analog monitors corresponding to the digital monitors via the RS-232C monitor
command.
The contents of the monitors are specified by the parameters: the parameter MN (First analog
monitor) for the output MON1 (First analog monitor) and the parameter MX (Second analog
monitor) for the output MON2 (Second analog monitor).
Besides the contents of monitor, you may freely set the output data range and the offset value to
the monitored data.
Table 7-36: Input/output and paramter related to analog monitor
Category Name (code)
Function
Initial
setting
Data range
MON1
First analog monitor
–
Cont
rol
output
MON2
Second analog monitor
–
0 to 5 [V] output,2.5 [V] center
MN
First analog monitor
0
0 to 8
Refer to
“
Table 7-37: Preset analog monitor.
”
Or input
MN
+
Monitor code
.
MNR
First analog monitor range
10.000
Data per +2.5 [V]
(Depends in the parameter MN.)
MNY
First analog monitor offset
0.000
Monitor output when the center is 2.5 [V]...
(Depends on the parameter MN.)
MX
Second analog monitor
0
0 to 8
Refer to “Table 7-37: Preset analog monitor.”
Or input
MX
+
Monitor code
.
MXR
Second analog monitor range
10.000
Data per + 2.5 [V]
(Depends on the parameter MX.)
Param
e
ter
MXY
Second analog monitor offset
0.000
Monitor output when the center is 2.5[V]...
(Depends on the parameter MX.)