![NSK Megatorque PS Series Скачать руководство пользователя страница 111](http://html.mh-extra.com/html/nsk/megatorque-ps-series/megatorque-ps-series_user-manual_1714650111.webp)
— 6-23 —
6.3.3. Pulse Train Command Positioning Operation
An input of pulse train command through the inputs of CWP (pulse train, CW) and CCW (pulse
train, CCW) of the CN2 connector (Input/Output) controls a positioning operation. The
frequency of input pulse determines rotational velocity while the total number of inputted pulse
determines the rotation amount.
Fig 6-15: Pulse train command operation and resolution
CN2: CWP
CN2: CCWP
Positioning
command
Pulse counter
2 621 440
Parameter CR
Monitor RP
Parameter PC
PC0:
CWP/CCWP
PC1:
pulse/direction
PC4:
øA/øB
Maximum input frequency:
1 [Mpps]