NOVO EconoFlo Series Скачать руководство пользователя страница 4

4

Model  

Number

Item  

Number

Capacity - Grains

Flow Rate

Mineral Tank 

Size (Inches)

Total Resin 

(cu.ft.)

Cabinet or Brine Tank 

Size Inches (WXDXH)

Salt Capacity 

(lbs)

Shipping 

Weight (lbs)

@ 10 lbs/cu ft 

@ 6 lbs/cu ft Factory 

Setting

@ 3 lbs/cu ft 

Service 
USGPM

Backwash 

USGPM

EFC20

2117

19,875

16,500

10,500

8

2

9X35

0.75

13.8 X 23.6 X 34.5

225

93

EFC30

2118

26,500

22,000

14,000

10

2.4

10X35

1

13.8 X 23.6 X 34.5

225

110

EFT20

2119

19,875

16,500

10,500

8

2

9X35

0.75

16.6X 16.7 X 61

230

93

EFT30

2120

26,500

22,000

14,000

10

2.4

10X35

1

16.6X 16.7 X 61

230

110

EFT40

2121

33,125

27,500

17,500

12

2.4

10X47

1.25

16.6X 16.7 X 61

230

141

EFT60

2122

53,000

44,000

28,000

13

3.5

12X52

2

18.9 X 18.9 X65.6

270

158

EFT90

2123

79,500

66,000

42,000

15

5

14X65

3

24.6 X 24.6 X 84

700

244

Regeneration Type

Co current / Down Flow

Plumbing Connections

Includes 3/4” 90°Elbows & 1” Straight NPT

Resin Type

Aquafine 8% High Capacity Ion Exchange Resin

Electrical Requirements

Input 120V 60 Hz - Output 12V 650mA

Water Temperature

Min. 40°F and Max. 110°F (4°C - 43°C). Fahrenheit

Water Pressure

Min. 30 - Max. 125 psi

SPECIFICATION

HOW YOUR WATER CONDITIONER WORKS

 

Water softeners remove hardness in the water by exchanging particles in the water, or ions. They remove hard ions such as calcium and magnesium in the water by trading it 

for sodium ions producing soft water. Unlike the calcium and magnesium, sodium stays dissolved in water and does not form a scale. Sodium also does not interfere with the 

cleaning action of soaps. The sodium is released by a charged resin contained in the softener, this resin also traps the calcium and magnesium ions. Eventually this resin releases 

all of its sodium and has filled up with other ions, so it then must be regenerated. Regeneration is accomplished by washing the resin with a salt saturated brine solution that 

removes the calcium and magnesium while replenishing the sodium. This is why the softener requires a brine tank and salt. The water softener can run for days before running 

out of sodium, and when it does, the sodium is replenished in only a matter of a few hours

When using a softener to remove both hardness and dissolved iron it is important that it regenerates more frequently than ordinarily would be calculated for hardness removal 

alone. Although many factors and formulas have been used to determine this frequency, it is recommended that the softener be regenerated when it has reached 50–75% of the 

calculated hardness alone capacity. This will minimize the potential for bed fouling.

 

If you are operating a water softener on clear water iron, regular resin bed cleaning is needed to keep the bed from coating with iron. Even when operating a softener on water 

with less than the maximum of dissolved iron, regular cleanings should be performed. Clean every six months or more often if iron appears in your conditioned water supply. Use 

resin bed cleaning compounds carefully following the directions on the container.

Upon installation the following information will be displayed or is easily  

accesible (see page 17 for key pad configuration) please review for your  

continued satisfactory operation of this product: 

Date and Time
Gallons Remaining or Days Remaining
Hardness:

 This can be adjusted seasonally if necessary and only upon recommendation 

of your installer or dealer. Most often this is set at installation for worst case hardness by 

the installer. 

Number of People:

 This can be adjusted seasonally if necessary and only upon recom-

mendation of your installer or dealer. Most often this is set at installation for worst case 

hardness by the installer. 

Reserve Capacity

: calculated as 75 gallons per person

Manual Regen Delay:

 – generally used after servicing the valve so that it will 

regenerate at the standard preset regeneraton time.  to regenerate immediately either 

turn the center knob slightly or change to Immediat and press settings.

Regen Time:

 This is the time of day that the conditioner is scheduled to regenerate, 

this is factory set to 2:00 a.m.  it can be adjusted (see page 34)

NOTE

In normal operation the display will not be back lit. 

You can press any button to back light the display. 

Содержание EconoFlo Series

Страница 1: ...nt maintenance procedures for the continued proper operation of your unit These MUST be performed regularly for your warranty to remain valid 2 Read all instructions carefully before operation 3 Avoid...

Страница 2: ...ING BRINE TANK 14 INSTALLATION 15 OPERATION STARTUP INSTRUCTIONS 17 DURING REGENERATION PLUMBING SYSTEM CLEAN UP 19 MAINTENANCE INSTRUCTIONS AND SCHEDULE 20 RES UP FEEDER INSTALLATION INSTRUCTIONS 22...

Страница 3: ...ls of iron manganese sulfur and sediments Damage to pistons seals and or spacers within the control valve are not covered in this warranty due to the harsh environment It is recommended to regularly i...

Страница 4: ...tener can run for days before running out of sodium and when it does the sodium is replenished in only a matter of a few hours When using a softener to remove both hardness and dissolved iron it is im...

Страница 5: ...g The manufacturer reserves the right to make product improvements which may deviate from the specifications and descriptions stated herein without obligation to change previously manufactured product...

Страница 6: ...3 159 7 20 3 x 37 4 21 9 x 21 9 x 72 2 385 0 174 2 BTR 200 Grey 53 0 200 3 23 0 x 40 5 24 6 x 24 6 x 84 700 0 316 7 All brine tanks come with salt grid safety float and brine well VDOW JULG V VWHP VD...

Страница 7: ...ollowing 1 Control Valve 2 Tank 3 Parts Box 4 Owners Manual 5 Drain Hose Clamp Not included in some brands 6 Brine Tank Assembly UNPACKING INSPECTION OF TWIN TANK MODEL 1 Control Valve 2 Tank Distribu...

Страница 8: ...Not Included with some models 5 Brine Tank Assembly 2 Control Valve 3 Media Box Qty depends on Models Distributor Tube Inside the Tank Media Inside the Tank Media Type will depend on what models were...

Страница 9: ...60010006 Bypass Tool 60010026 O Rings Attached 60090010 2 X 3 4 Elbow Adapter 60010630 Transformer 92360 Grease Packet UNPACKING INSPECTION OF CABINET MODEL 1 Cabinet with Valve attached EFC20 EFC30 2...

Страница 10: ...9 SEP 9 Q 2020 A OCT A 10 B NOV B 11 C DEC C 12 D 13 E 14 F 15 G 16 H 17 I 18 J 19 K 20 L 21 M 22 N 23 O 24 P 25 Q 26 R 27 S 28 T 29 U 30 V 31 Valve Serial CheckValveType andValve Serial The right St...

Страница 11: ...ge them Tools Required for Installation NOTE We recommend installation only be completed by a competent installer or plumbing professional to insure this product is installed in accordance with local...

Страница 12: ...alve and Screw theValve inside theTank such that the power cord doesn t get caught between the valve and the tank d Unplug the riser tube carefully position the valve over it and turn the valve into t...

Страница 13: ...valve solder the threaded copper adapters to the copper pipe and then usingTeflon tape screw the assembly into the bypass valve Do not use pipe thread compound as it may attack the material in the val...

Страница 14: ...he brine line already come installed from the factory Leave the other end of the brine line tube inside the brine tank f For installation of brine tank at the installation site pull the other end of t...

Страница 15: ...R FLOW NOTE Check local plumbing codes in regards to requirements for use of Check Valve or back flow prevention or vacuum breaker Connect Softener to the HousePlumbing Any solder joints near the valv...

Страница 16: ...CE THERE ARE RAISED ARROWS ON THE BYPASS ASSEMBLY INDICATING DIRECTION OF WATER FLOW Connect Softener to the HousePlumbing Any solder joints near the valve must be done before connecting any piping to...

Страница 17: ...ow Do not add salt to the brine tank at this time BTR 100 2 5 US Gallons 1 Connect theTransformer to theValve Plug the 12 volt transformer into a 120 VAC 60 Hz outlet Familiarize with Button Configura...

Страница 18: ...7 for Key Pad Configuration Calculating Compensated Hardness forWater where Iron or Manganese is Present From your water analysis Iron x 4 grains of hardness and or Manganese x 8 grains of hardness Th...

Страница 19: ...NG SYSTEM CLEAN UP The following procedures are guidelines only but have proven successful in most instances Under no circumstances should any procedure outlined below be followed if contrary to the a...

Страница 20: ...ILURE TO FOLLOW BASIC MAINTENANCE SCHEDULE WILL RESULT IN THE UNIT FAILING TO OPERATE PROPERLY AND VOID YOUR WARRANTY CAUTION Liquid brine will irritate eyes skin and open wounds gently wash exposed a...

Страница 21: ...alt in tank will both effect the units capacity and result in hardness slippage Should either of these situa tions happen or the unit fails to regenerate for any other reason please first correct the...

Страница 22: ...e Brine Well lid 2 Measure 2 inches from the top of the tank beside the oblong molding 6 Take off the cover of the Res Care bottle Insert the wick making sure it touches the bottom of the bottle Inser...

Страница 23: ...ditioner installation has a 3 valve bypass system first open the valve in the bypass line then close the valves at the conditioner inlet outlet b If the conditioner has an integral bypass valve put it...

Страница 24: ...seal spacer assembly grease it with silicone lubricant and put back in 5 Replace piston assembly followed by timer assembly 6 Replace the piston assembly and reverse following steps in this section Re...

Страница 25: ...ved before Step 2 If there are TB L and TB H meter type options in PCB programming select TB H Ifthevalveprogramminghasno TB L and TB H options changethemeterratiotothe newvalueasperchartbelow For 65...

Страница 26: ...Pull the drain line clip and remove the drain line elbow and washer 2 Clean replace drain line washer REPLACING PCBS Remove PCBs by removing the screws shown in the picture Drain Line Elbow REPLACE D...

Страница 27: ...istrubutor Valve Media Bed Softener Downflow SingleTank EFC T20 9 x 35 25010028 50010005 10010032 95600 EFC T30 10 x 35 25010043 50010005 95601 EFT40 10 x 47 25010070 50010005 95606 EFT60 12 x 52 2501...

Страница 28: ...0661 Screw ST4 2 12 LargeWafer 1 B17 60010662 Brine Gear 1 B16 60010663 Main Gear 1 B15 60010664 Bnt165 Drive Gear 1 B14 60010677 Idler Gear 1 B13 60010103 Spring Idler 1 B12 60010666 Spring Retainer...

Страница 29: ...ST3 5 13 2 60125 60010027 60032 Piston Assembly Seals and Spacer Kit BrineValve Item s For All Injector Assemblies and Brine Line and Drain LineWashers Part Part Description 60010110 BLFC BUTTON 2 0...

Страница 30: ...4 Bypass Shaft Outlet 1 20 60095614 05030013 O ring 30 2 65 2 19 60010740 05056149B Shaft Seal 2 18 60010069 05056172N Plug Clip Red 2 17 60010740 21709004 Shaft Clip Red 2 16 60010209 05056146M Bypas...

Страница 31: ...020019 TANK ASSY 935 NAT 1 25020020 TANK ASSY 1035 NAT 10 50010020 Distribution Assy 1035 1 9 18280 Top Cone 1 8 60095097 1 BypassValve Assy 1 7 765 ControlValve Grey 1 6 55010031 Softener Low Cover 1...

Страница 32: ...n drain line 1 Air in water system Check well system for proper air eliminator control 2 Incorrect drain line flow control DLFC button Check for proper flow rate F Too much water in brine tank 1 Plugg...

Страница 33: ...be adjusted by a qualified person MASTER PROGRAMMING PROGRAMMING LEVELS There are 3 levels to the valve program Master options and Factory options are typically adjusted at the factory These options l...

Страница 34: ...60 MIN BRINE 60 MIN RINSE 10 MIN RINSE 10 MIN RINSE 10 MIN REFILL 11 1 MIN REFILL 11 1 MIN REFILL 11 1 MIN REG TIME 12 00 AM BACKWASH 10 MIN RINSE 10 MIN SOFTENER MODE FILTER MODE CAUTION Thevaluesint...

Страница 35: ...0 0s 0 0s 0 0s 0 0s 0 0s REFILL 2 0s 2 0s 2 0s 2 0s 2 0s SALT SET 10 12 LBS 12 LBS 12 LBS 12 LBS PRESS UP DOWN FOR 8 SECONDS PRESS UP OR DOWNTO CHANGE PRESS SELECTTO ACCEPT METER DELAYED METER DELAYED...

Страница 36: ...Toll Free 1 877 288 9888 Regina SK Cambridge ON Carmel IN Pottstown PA Phoenix AZ 54816 11 18...

Отзывы: