22
23
2 X Screws
Back Cover
1.
Disconnect the meter cable from the meter. (If flow
meter is attached)
2.
Remove two screws from the back of the valve cover
3.
Remove the piston screw and washer from the piston
rod.
4.
Remove the two screws from the powerhead as shown
5.
Life the powerhead from the valve body assembly
6.
Replace the powerhead by reverse following the steps in this section
Piston Screw Washer
2 X Screws from Powerhead
Powerhead
Assembly
Valve Body
Assembly
Meter Cable
50.82481457314046%
TIMER REPLACEMENT
Before Servicing
1.
Turn off water supply to conditioner :
a.
If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line, then close the valves at the conditioner inlet & outlet.
b. If the conditioner has an integral bypass valve, put it in the bypass position.
c. If there is only a shut-off valve near the conditioner inlet, close it.
2.
Relieve water pressure in the conditioner by stepping the control into the backwash position momentarily. Return the control to the In Service position.
3.
Unplug Electrical Cord from outlet.
4.
Disconnect drain line connection.
SERVICING ECONOFLO VALVE
CAUTION!
Disassembly while under
pressure can result in flooding.
Always follow these steps prior
to servicing the valve.
WARNING!
ELECTRICAL SHOCK
HAZARD!
UNPLUG THE UNIT
BEFORE REMOVING THE
COVER OR ACCESSING ANY
INTERNAL CONTROL PARTS