Sample
Connection
Sample
Connection
SERVICE
BYPASS
Sample
Connection
Sample
Connection
SERVICE
BYPASS
BYPASS
DURING REGENERATION
Automatic Water Bypass
The regeneration cycle lasts approximately 1.5 hours to 3.0 hours depending on the specific model, after which treated water service will be restored. During regeneration,
untreated water is automatically bypassed for use in the household. Hot water should be used as little as possible during this time to prevent hard water from filling the water
heater.
IMPORTANT: This is why the automatic regeneration is set for sometime during the night and manual regenerations should be performed when little or no
water will be used in the household.
Manual Water Bypass
In case of an emergency or when performing filter maintenance, you can isolate your water softener from the water supply using the bypass valve located at the back of the
control. In normal operation the bypass is open with the ON/OFF knobs in line with the INLET and OUTLET pipes. To isolate the filter, simply rotate the knobs as indicated below in
figure 1, until they stop. You can use your water related fixtures and appliances as the watersupply is bypassing the softener. However, the water you use will be hard. To resume
treated service, open the bypass valve by rotating the knobs counterclockwise.
Please make sure bypass knobs are completely open otherwise the unfiltered water
will bypass your conditioner.
New Sounds
You may notice new sounds as your water softener operates. The regeneration cycle lasts approximately 1.5 hours to 3.0 hours depending on the specific model. During this time,
will be able to hear water running intermittently to the drain, depending on proximity of the unit to sleeping area and time of regeneration.
PLUMBING SYSTEM CLEAN-UP
The following procedures are guidelines only but have proven successful in most instances. Under no circumstances should any procedure outlined below be followed if contrary
to the appliance manufacturer’s instructions. Should there by any questions concerning the advisability of performing a procedure, it is strongly recommended the manufactur-
er’s authorized service outlet be consulted prior to performing the procedure.
Water Heater
If
the water heater has been exposed to both iron and hardness for a long period of time, replacement of the heater tank maybe the only practical solution to prevent continued
staining originating from this source. After completing the installation of the conditioner, clean the water heater by following these instructions:
1.
Shut off energy supply to water heater and close heater inlet water valve.
2.
Drain hot water tank completely. Open inlet water valve allowing heater tank to be refilled with iron-free water. Continue flushing until water runs clear to drain.
3.
If, after approximately 30 minutes flushing, water does NOT clear, terminate flushing operation. Refill hot water heater with water and pour approximately 1/2 gallon of
household bleach into top of heater tank. Allow bleach solution to stand in tank for 20 to 30 minutes. Flush tank
Dishwasher
Consult owners’ handbook and follow manufacturer’s instructions.
Toilet Flush Tanks
Prior to commencing installation of the filter system, pour 4 to 6 ounces of resin mineral cleaner Pro-Rust Out or or other suitable cleaner such as CLR that contains a mild acid
into flush tanks and bowls and let stand. When installation is completed, flush toilets several times with conditioned water. If stains or deposits return check that lines are
connected to treated water. Repeat procedure until clear. again until water is clear at drain. Turn energy supply on.
NOTE
If water does not clear in
approximately 10 minutes,
water heater may need
replacement.
Fig. 1