Service manual
XLP 504 / XLP 506
05/2018 | 04
194
Malfunctions
1511 Bar Parm Error
Error level1
Parameters to a barcode command is wrong or does not conform with specs.
Modify the bar code command.
1512 Code128 Mode Err
Error level1
Code128 barcode command specifying mode type other than 'AUTO'.
Modify the bar code command.
1513 Wrong Mode
Error level2
Coda block barcode command specifying mode type other than 'F'.
Modify the bar code command.
1514 ^BX Parm Err.
Error level2
Data Matrix bar code command specified an escape sequence character. This is not supported in
this printer.
Modify the bar code command.
1515 Conv to ECC200
Error level1
Data Matrix barcode command specified non ECC200 level. Program is attempting to convert to
ECC200.
Modify the bar code command.
1516 Bad Drive: x
Error level2
The selected drive letter („x“) is not valid. (We support only 'R' and 'B').
Select a valid drive letter.
1517 Mask String: x
Error level2
The mask string used in ^SF command is not supported.
Modify the print job.
1518 Bad Format: x
Error level2
The graphic format selected is not supported by ZPL II Emulation (Compressed binary and PNG
format).
Convert graphic into a supported format.
1519 Cmd Init Error
Error level1
Содержание XLP 504
Страница 1: ...Edition 9 5 2018 Translation of original version SERVICE MANUAL XLP 504 XLP 506 Label printer ...
Страница 2: ......
Страница 218: ...Service manual XLP 504 XLP 506 05 2018 04 218 Malfunctions System Memory Font downl area System Memory Free store size ...
Страница 238: ...Service manual XLP 504 XLP 506 05 2018 06 238 Appendix WIRING DIAGRAMS See next pages ...
Страница 248: ...Novexx Solutions GmbH Ohmstraße 3 85386 Eching Germany 49 8165 925 0 www novexx com ...