Service manual
XLP 504 / XLP 506
05/2018 | 03
29
Service Mechanics
Replacing the ribbon end sensor
Checking the ribbon end sensor: See chapter
Tools
• Torx screwdriver, size 10
• Side cutters
Removing
1. Remove screw [22A], take off the sensor [22B].
2. Open cable clamps, cut cable ties. Remove cable
from cable clamps.
3. Unplug end of cable from CPU board.
Installation
Perform the installation in the reverse order to the re-
moval. Note the following:
Connect sensor to plug CN906 [23A] on CPU
board.
For a detailed connection diagram, see chapter
Install the cable so that it does not contact any mov-
ing parts.
[22] Ribbon end sensor (B).
[23] Connection from Ribbon end sensor to CPU board.
A
B
A