NO ENTRY REQUIRED
Shipped Configured and Enabled
Intelligent Regen constantly monitors the
regeneration inlet and outlet temperatures
and controls them to optimize the energy
and dew point performance of the dryer.
The control will lower (or raise) the
regeneration inlet temperature by 5 F. (2.4
C) each time the desiccant wheel rotates to
ensure that adequate, but not excess heat,
is used to maintain the dryer dew point
performance while insuring that no excess
heat is used and wasted. Once the dryer
has optimized itself, changes cease. The
system insures the best dryer performance
despite the materials processed, their
moisture level or any changes in dryer
processing rate thereby saving energy and
improving performance.
If there is an extended delay at the
process machine, it is easier to re-set a
reduced drying temperature or shut the
Process Heater “OFF” on the QuickOp
scree
n but… this menu can be used to
put or remove the dryer from second set
point while unattended. When the
system is enabled an
icon will be
displayed on the operations screens in
the upper left corner.
Changing From F° to C°
10.3 Rarely Used Screens
Changing from F° to C° is a common
reason to access this screen.
Obtain password from NOVATEC.
Press in upper LH corner of any
screen to view NOVATEC Menu.
Enter NOVATEC Password. Press
Basic Machine Configuration then
Configuration Menu 1. Press F° and it
will change to C°.
Press
then
to exit.
NOTE:
If you switch from F to C
you must also adjust the dip
switch on the PLC. See page 17