NWDC
IM 26 MAR 2014 © 2014 Novatec, Inc. All Rights Reserved
Page 27
[Type text]
[Type text]
NWDC IM 26 MAR 2014
The Password Menu Screen has listed 6
other screens with a space for passwords
and a selector pad to either enable or
disable the password. Any 5-digit number
may be set as a password. To enable the
password and protect the screen, enter the
password and depress the associated pad.
The pad will show “Enabled” and the
protection will become active after leaving
this screen.
The Password Entry screen will appear
whenever the system is directed to a screen
that has password protection associated with it.
If the password is enabled, the screen will
remain up until the correct password is entered.
If the password is not enabled, the screen will
appear briefly before continuing to the selected
screen.
This screen is not necessary unless you want
to enter values for a resin that you rarely dry
and do not want to put it in the Resin Menu.
Here, the Process values for hopper #1 can
be set or adjusted. The high and low
deviation, (range for the alarm,) second set
point, and active set point values are
available. Values must be entered as positive
values. The Overtemp SP is the temperature,
at which, the hopper blower and temperature
control will shut down.
NOTE: If you change the factory pre-set values
(which are fine for just about any drying scenario)
they will apply to every resin you dry so be sure to
re-enter the factory pre-sets.
.
STEP#5:
Depress
then Password Menu
Step #6:
Depress
then Process Menu