background image

DISCLAIMER

NS350

  

Operating Manual

27

Information in this document is provided solely in connection with NOVASAIL LTD 
products. NOVASAIL LTD reserves the right to make changes, corrections, 
modifications or improvements to this document and the products described herein at 
any time, without notice.

All NOVASAIL LTD products are sold pursuant to NOVASAIL LTD’s terms and 
conditions of sale.

Purchasers are solely responsible for the choice, selection and use of the NOVASAIL 
LTD products described herein, and NOVASAIL LTD assumes no liability whatsoever 
relating to the choice, selection or use of the NOVASAIL LTD products described 
herein.

UNLESS OTHERWISE SET FORTH IN NOVASAIL LTD’S TERMS AND 
CONDITIONS OF SALE,  NOVASAIL LTD DISCLAIMS ANY EXPRESS OR IMPLIED 
WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF NOVASAIL LTD 
PRODUCTS, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (AND THEIR 
EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
UNLESS EXPRESSLY APPROVED IN WRITING BY AN AUTHORIZED NOVASAIL 
LTD REPRESENTATIVE, NOVASAIL LTD PRODUCTS ARE NOT RECOMMENDED, 
AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, 
LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR 
SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL 
INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE.  

Resale of NOVASAIL LTD products with provisions different 
from the statements and/or technical features set forth in this 
document shall immediately void any warranty granted by 
NOVASAIL LTD for the NOVASAIL LTD product or service 
described herein and shall not create or extend in any manner 
whatsoever, any liability of NOVASAIL LTD. 

Содержание NS350

Страница 1: ...Operating Manual v2 0...

Страница 2: ...modes 7 Magnetic heading compass mode 8 Wind shift indicator mode 8 Tack incator mode 10 ROLL angle indicator mode 12 TIMER mode 13 Advanced Operations 14 SET mode 14 Exit timer mode 15 Tack mode tim...

Страница 3: ...grams than any existing system wired or wireless It is also waterproof and robust being made of bombproof polycarbonate and anodized aluminium Powered with only one AA battery the NS350 gives sailors...

Страница 4: ...he mounting location should be as far as possible from any magnetic objects to avoid any interference with the compass sensor The NS350 should be mounted as close as possible to the vertical and horiz...

Страница 5: ...ndicator WIN Tack Indicator TAK Roll angle indicator ROL TIMER TIM Battery Backlight Data Mode Controls and display description Start stop the NS350 Start stop the backlight Memorize the wind directio...

Страница 6: ...f the device does not turn on you need to check if the battery is fully charged that the battery compartment is dry and the polarity is correct Note Alkaline batteries should be used in order to resul...

Страница 7: ...h on off the backlight you will not make any selection and therefore will not change any parameter Switching modes and sub modes To have two different separate readings first choose the mode and sub m...

Страница 8: ...ity When sailing with light winds and flat seas High sensitivity allows you to appreciate very small wind variation MHM Magnetic Heading Medium sensitivity Medium sensitivity is more suitable for race...

Страница 9: ...board and port is not defined You can do starboard then port or vice versa The WIN mode displays an angle in degrees which corresponds to the difference between the tack line direction and the current...

Страница 10: ...immediate action tacking Note To use this mode the tack lines on starboard and port must have been memorized in WIN mode When the boat is in a lifting wind the display will show a bar graph Each bar m...

Страница 11: ...value set in SETUP mode the timer value and TAK are displayed alternatively see SET mode page 14 If the boat goes fig 2 TAK mode display when sailing with a lift wind on starboard Display I I I I I Wi...

Страница 12: ...en followed by the the value of the deviation from the wind direction Roll angle indicator mode ROL Used in Roll angle indicator ROL mode the NS350 displays the roll angle of the boat The angle range...

Страница 13: ...chronize the TIMER to the nearest minute When the TIMER is running at any time you can resynchronize to the upper or lower minute Press the arrow to resynchronize the value to the upper minute Press t...

Страница 14: ...ET mode Press and the upper screen simultaneously SET is displayed on the data line of the upper screen Each parameter is displayed on the mode line of the lower screen Select the required value for e...

Страница 15: ...e data line of the upper screen Press until ETI Exit Timer mode is displayed on the data line of the lower screen Use the arrows to select the desired exit mode for your NS350 Press to store the value...

Страница 16: ...1 to 90 seconds Switch off your NS350 Press and the upper screen simultaneously SET is displayed on the data line of the upper screen Press until TAK is displayed on the mode line of the lower screen...

Страница 17: ...which the user has to follow the sequence described below To allow the maximum accuracy of the calibration procedure it is recommended to perform this outdoors to avoid any magnetic disturbing fields...

Страница 18: ...tory calibration values can be restored at any time by setting the RES menu to ON in the SET mode Step 1 1 is displayed on the lower screen The NS350 must be oriented as follows Push the select key wh...

Страница 19: ...the end of step 2 Step 3 3 is now displayed on the lower screen The NS350 must be oriented as follows Push the select key when ready The NS350 will enter the calibration along the axis After a few se...

Страница 20: ...the end of step 4 Step 5 5 is now displayed on the lower screen The NS350 must be oriented as follows Push the select key when ready The NS350 will enter the calibration along the axis After a few se...

Страница 21: ...the end of step 6 Step 7 7 is now displayed on the lower screen The NS350 must be oriented as follows Push the select key when ready The NS350 will enter the calibration along the axis After a few se...

Страница 22: ...y the end of step 8 Step 9 9 is now displayed on the lower screen The NS350 must be oriented as follows Push the select key when ready The NS350 will enter the calibration along the axis After a few s...

Страница 23: ...e select key when ready The NS350 will enter the calibration along the axis After a few seconds 3 beeps will be emitted to notify the end of step 10 The NS350 will store the new values and switch off...

Страница 24: ...NS350 Operating Manual 24 Document History Version 1 0 First version Version 2 0 1 12 2009 Updated pictures...

Страница 25: ...NS350 Operating Manual 25...

Страница 26: ...holder The product has to be registered using the online service available on the Novasail web site www nova sail com Please submit the proof of purchase Invoice when requesting service The actual cos...

Страница 27: ...S OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND OR SALE OF NOVASAIL LTD PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND THEIR EQUI...

Страница 28: ...2008 NOVASAIL All rights reserved www nova sail com...

Отзывы: